Veterinary MedicineOncologyRadiologyDiagnostic ImagingDiagnostic RadiologyThoracic ImagingComputed TomographyContrast AgentsContrast MediaMediastinal ImagingThoracic Vascular ImagingVascular ImagingCohen's Kappa InterpretationContrastContrast Dose OptimizationContrast-enhanced Computed TomographyContrast-enhanced Imaging Dose OptimizationContrast-enhanced Thoracic ImagingRadiation Dose ManagementRadiation Dose Reduction
Objective To investigate the visualization of mediastinal lymph nodes during thoracic CT employing a multiphasic contrast media (CM) protocol. Methods Institutional review board approved retrospective study consisting of 300 patients with known chest malignancy. Patients were allocated to one of two CM protocols: Protocol A, consisted of dual bolus (Phase 1:100 ml CM followed by 100 ml saline chaser) i.v. injected at 2.5 ml s−1; Protocol B employed 100 ml of CM using a multiphasic injection protocol (Phase 1 and 2:60 ml contrast and saline, followed by Phase 3 and 4:40 ml contrast and saline injected at 2.5 ml s−1) with a fixed scan delay of 70 s for each acquisition. Attenuation profiles of the thoracic arteries and veins were calculated as well as the arterio-venous contrast ratios (AVCR). Receiver operating characteristic (ROC), visual grading characteristic (VGC), and Cohen's kappa analysis were assessed. Results Arterial opacification was up to 24% (p < 0.032) higher in protocol B than A, whereas, in the veins it was significantly lower in protocol B than A, with a maximum reduction of up to 84% (p < 0.0001). There was no statistical significance between the central and peripheral pulmonary arteries [>263 Hounsfield units (HU)] in each protocol. Protocol B, demonstrated significant improvement in AVCR at various anatomical sites (p < 0.002). Radiation dose was significantly reduced in protocol B compared to A (p < 0.004). Both ROC and VGC demonstrated significantly higher Az score for protocol B compared to A (p < 0.0001) with an increased inter reader agreement from poor to excellent. Conclusion Employing a multiphasic CM protocol significantly improves opacification of the thoracic vasculature and visualization of mediastinal lymph nodes during thoracic CT. Advances in knowledge Uniform opacification between thoracic arteries and veins increases the delineation between vasculature and lymph nodes, reduces radiation dose when employing a multiphase contrast media injection protocol.
17
Takeshi Nakaura, Shinichi Nakamura, Natsuki Maruyama et al. · Radiology · 2012 · 133 citations
Takeshi Nakaura, Kazuo Awai, Yumi Yauaga et al. · Investigative Radiology · 2008 · 84 citations
Medicine, Cardiology, Radiology +17
Cervical lymphadenopathy: what radiologists need to know
Vincent Chong · Cancer Imaging · 2004 · 73 citations · Full text
Medicine, Gynecology, Radiology +11