Journal of Applied Clinical Medical Physics · 2018 · 10 citations · 29 references
MedicineOncologyRadiation OncologyClinical Radiation OncologyRadiation DosimetryTreatment PlanningIntensity-modulated RadiotherapyPediatric Radiation OncologyRadiation TherapyRadiation Treatment PlanningThree-dimensional Conformal RadiotherapyTreatment Planning Dose Calculation3D-conformal RadiotherapyExcess Absolute Risk ModelingFlattening Filter-free BeamsPlan Quality AssessmentPlan Quality MetricsRadiation Dose VerificationRadiation-induced Second MalignanciesSecond Cancer Risk
Abstract Pediatric patients suffering from ependymoma are usually treated with cranial or craniospinal three‐dimensional (3D) conformal radiotherapy (3DCRT). Intensity‐modulated techniques spare dose to the surrounding tissue, but the risk for second malignancies may be increased due to the increase in low‐dose volume. The aim of this study is to investigate if the flattening filter free (FFF) mode allows reducing the risk for second malignancies compared to the mode with flattening filter (FF) for intensity‐modulated techniques and to 3DCRT. A reduction of the risk would be advantageous for treating pediatric ependymoma. 3DCRT was compared to intensity‐modulated radiation therapy (IMRT) and volumetric‐modulated arc therapy (VMAT) with and without flattening filter. Dose–volume histograms (DVHs) were compared to evaluate the plan quality and used to calculate the excess absolute risk (EAR) to develop second cancer in the brain. Dose verification was performed with a two‐dimensional (2D) ionization chamber array and the out‐of‐field dose was measured with an ionization chamber to determine the EAR in peripheral organs. Delivery times were measured. Both VMAT and IMRT achieved similar plan quality in terms of dose sparing in the OAR and higher PTV coverage as compared to 3DCRT. Peripheral dose in low‐dose region, which is proportional to the EAR in organs located in this region, for example, gonads, bladder, or bowel, could be significantly reduced using FFF. The lowest peripheral EAR and lowest delivery times were hereby achieved with VMAT FFF . The EAR calculated based on DVH in the brain could not be reduced using FFF mode. VMAT FFF improved the target coverage and homogeneity and kept the dose in the OAR similar compared to 3DCRT. In addition, delivery times were significantly reduced using VMAT FFF . Therefore, for radiotherapy of ependymoma patients, VMAT FFF may be considered advantageous for the combination of Elekta Synergy linac and Oncentra External Beam planning system used in this study.
29
Statistical Power Analysis for the Behavioral Sciences
Keith E. Muller, Jacob Cohen · Technometrics · 1989 · 83.9K citations
A Simple Sequentially Rejective Multiple Test Procedure
Sture Holm · Scandinavian Journal of Statistics · 1979 · 21.8K citations
A technique for the quantitative evaluation of dose distributions
Daniel A. Low, William B. Harms, Sasa Mutic et al. · Medical Physics · 1998 · 2.9K citations · Full text