Publication | Open Access
Multi-angle light scattering as a process analytical technology measuring real-time molecular weight for downstream process control
52
Citations
8
References
2018
Year
For many protein therapeutics including monoclonal antibodies, aggregate removal process can be complex and challenging. We evaluated two different process analytical technology (PAT) applications that couple a purification unit performing preparative hydrophobic interaction chromatography (HIC) to a multi-angle light scattering (MALS) system. Using first principle measurements, the MALS detector calculates weight-average molar mass, M<sub>w</sub> and can control aggregate levels in purification. The first application uses an in-line MALS to send start/stop fractionation trigger signals directly to the purification unit when preset M<sub>w</sub> criteria are met or unmet. This occurs in real-time and eliminates the need for analysis after purification. The second application uses on-line ultra-high performance size-exclusion liquid chromatography to sample from the purification stream, separating the mAb species and confirming their M<sub>w</sub> using a µMALS detector. The percent dimer (1.5%) determined by the on-line method is in agreement with the data from the in-line application (M<sub>w</sub> increase of approximately 2750 Da). The novel HIC-MALS systems demonstrated here can be used as a powerful tool for real-time aggregate monitoring and control during biologics purification enabling future real time release of biotherapeutics.
| Year | Citations | |
|---|---|---|
Page 1