Journal of Interventional Cardiac Electrophysiology · 2018 · 19 citations · 9 references
EngineeringBioengineeringBiomedical EngineeringElectrophysiologyAtrial ElectrophysiologyBioelectronic MedicineCardiac PacingImplant MaterialsImplantable Biomedical DevicesPacemaker CareCardiac PacemakersLeadless PacemakersOperator Learning CurvePacemaker ProgrammingPermanent Pacemaker Therapy
PURPOSE: Use of novel medical technologies, such as leadless pacemaker (LP) therapy, may be subjected to a learning curve effect. The objective of the current study was to assess the impact of operators' experience on the occurrence of serious adverse device effects (SADE) and procedural efficiency. METHODS: Patients implanted with a Nanostim LP (Abbott, USA) within two prospective studies (i.e., LEADLESS ll IDE and Leadless Observational Study) were assessed. Patients were categorized into quartiles based on operator experience. Learning curve analysis included the comparison of SADE rates at 30 days post-implant per quartile and between patients in quartile 4 (> 10 implants) and patients in quartiles 1 through 3 (1-10 implants). Procedural efficiency was assessed based on procedure duration and repositioning attempts. RESULTS: Nanostim LP implant was performed in 1439 patients by 171 implanters at 60 centers in 10 countries. A total of 91 (6.4%) patients experienced a SADE in the first 30 days. SADE rates dropped from 7.4 to 4.5% (p = 0.038) after more than 10 implants per operator. Total procedure duration decreased from 30.9 ± 19.1 min in quartile 1 to 21.6 ± 13.2 min (p < 0.001) in quartile 4. The need for multiple repositionings during the LP procedure reduced in quartile 4 (14.8%), compared to quartiles 1 (26.8%; p < 0.001), 2 (26.6%; p < 0.001), and 3 (20.4%; p = 0.03). CONCLUSIONS: Learning curves exist for Nanostim LP implantation. Procedure efficiency improved with increased operator experience, according to a decrease in the incidence of SADE, procedure duration, and repositioning attempts.
9
A Leadless Intracardiac Transcatheter Pacing System
Dwight Reynolds, Gábor Zoltán Duray, Razali Omar et al. · New England Journal of Medicine · 2015 · 915 citations · Full text
Permanent Leadless Cardiac Pacing
Vivek Y. Reddy, Reinoud E. Knops, Johannes Sperzel et al. · Circulation · 2014 · 306 citations · Full text
Incidence and predictors of cardiac perforation after permanent pacemaker placement
Srijoy Mahapatra, Kevin A. Bybee, T. Jared Bunch et al. · Heart Rhythm · 2005 · 295 citations
Medicine, Cardiology, Surgery +11