Veterinary MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyNeuroradiologyComputed TomographyImage Quality AssessmentMedical ImagingRadiation Imaging DetectorsRadiographic AssessmentRadiographic ImagingEnergy-integrating DetectorsHigh-resolution ImagingImage Noise AssessmentPhoton Counting DetectionPhoton Counting ImagingPhoton-counting Computed TomographyPhoton-counting DetectorsSpatial Resolution Measurement
<h3>BACKGROUND AND PURPOSE:</h3> Evaluating abnormalities of the temporal bone requires high-spatial-resolution CT imaging. Our aim was to assess the performance of photon-counting-detector ultra-high-resolution acquisitions for temporal bone imaging and compare the results with those of energy-integrating-detector ultra-high-resolution acquisitions. <h3>MATERIALS AND METHODS:</h3> Phantom studies were conducted to quantify spatial resolution of the ultra-high-resolution mode on a prototype photon-counting-detector CT scanner and an energy-integrating-detector CT scanner that uses a comb filter. Ten cadaveric temporal bones were scanned on both systems with the radiation dose matched to that of the clinical examinations. Images were reconstructed using a sharp kernel, 0.6-mm (minimum) thickness for energy-integrating-detector CT, and 0.6- and 0.25-mm (minimum) thicknesses for photon-counting-detector CT. Image noise was measured and compared using adjusted 1-way ANOVA. Images were reviewed blindly by 3 neuroradiologists to assess the incudomallear joint, stapes footplate, modiolus, and overall image quality. The ranking results for each specimen and protocol were compared using the Friedman test. The Krippendorff α was used for interreader agreement. <h3>RESULTS:</h3> Photon-counting-detector CT showed an increase of in-plane resolution compared with energy-integrating-detector CT. At the same thickness (0.6 mm), images from photon-counting-detector CT had significantly lower (<i>P</i> < .001) image noise compared with energy-integrating-detector CT. Readers preferred the photon-counting-detector CT images to the energy-integrating-detector images for all 3 temporal bone structures. A moderate interreader agreement was observed with the Krippendorff α = 0.50. For overall image quality, photon-counting-detector CT image sets were ranked significantly higher than images from energy-integrating-detector CT (<i>P</i> < .001). <h3>CONCLUSIONS:</h3> This study demonstrated substantially better delineation of fine anatomy for the temporal bones scanned with the ultra-high-resolution mode of photon-counting-detector CT compared with the ultra-high-resolution mode of a commercial energy-integrating-detector CT scanner.
30
The Measurement of Observer Agreement for Categorical Data
J. Richard Landis, Gary G. Koch · Biometrics · 1977 · 78.9K citations · Full text
Photon Counting Energy Dispersive Detector Arrays for X-ray Imaging
Jan S. Iwanczyk, E. Nygärd, Meirav Oded et al. · IEEE Transactions on Nuclear Science · 2009 · 293 citations · Full text
Imaging findings of cochlear nerve deficiency.
Christine M. Glastonbury, H. Christian Davidson, H R Harnsberger et al. · PubMed · 2002 · 227 citations · Full text
Medicine, Audiology, Otolaryngology +17