IEEE Transactions on Power Electronics · 2018 · 59 citations · 32 references
EngineeringElectrical EngineeringLow-power DesignPower ElectronicsProcess ControlActive FiltersControl TheoryFeedback ControlPower ControlPower QualityPower System StabilityActive Power FilterControl System RobustnessCurrent ControlCurrent Control Of Power ConvertersDampingDelay CompensationResonanceTime-delay Compensation
This paper is focused on a dual-loop current control method (grid current loop and fundamental current loop) for digitally controlled LCL-type shunt active power filters (APFs). Normally, a proportional-resonant (PR) unit is used as the fundamental current controller, where the proportional part of PR unit actually serves as the proportional feedback of inverter-side current and provides a certain degree of damping for LCL resonance. However, its valid damping region is only up to one-sixth of the sampling frequency (f <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">s</sub> /6), which leads to less robustness to the grid impedance. To address this issue, a delay-compensation control link is proposed in this paper to replace the proportional part of the PR fundamental current controller and widen the effective damping region. As a result, the system robustness is improved without adding extra sensors or introducing an extra active damping loop. Theoretical analysis proves that it can obtain a wider damping region of (0, f <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">s</sub> /4). Moreover, a systematic controller parameter design criterion is studied. In particular, a numerical optimization algorithm is developed to optimize damping property, and a design method based on root locus plot and Bode diagram is presented to enhance harmonic compensation accuracy. Finally, experimental results implemented on a 30 kVA APF prototype have validated the feasibility of the proposed current controller and parameter design criterion.
32