International Transactions on Electrical Energy Systems · 2018 · 40 citations · 22 references
AgricultureElectrical EngineeringPower ElectronicsRenewable Energy IntegrationRenewable Energy SystemsDistributed Energy ResourcesPower QualityRenewable EnergyRenewable Energy Power ConversionSolar Photovoltaic SystemsVoltage RegulationActive Power FilterDistributed GenerationGrid IntegrationGrid Integration Of RenewablesGrid Integration Of Solar PowerReactive Power ControlThree-phase PowerVoltage Sag Mitigation
In UPQCDG, shunt APFs supply both active and reactive power, increasing VA burden and requiring higher ratings. The paper proposes a synchronous reference frame–based power angle control method for UPQCDG to enable efficient solar PV integration by sharing reactive power between series and shunt APFs, thereby reducing VA burden. The PAC method uses instantaneous three‑phase power estimation with existing UPQCDG measurements, and its performance was evaluated under nonlinear and reactive loads, solar PV generation, and grid disturbances such as voltage sags, swells, irradiation changes, and load variations. Real‑time simulation on an Opal‑RT FPGA engine with sub‑microsecond steps confirmed the effectiveness of the PAC method.
In this paper, a new synchronous reference frame theory–based power angle control (PAC) method for unified power quality conditioner with distributed generation (UPQCDG) is proposed for effective grid integration of solar PV. In UPQCDG, shunt active power filter (APF) feeds power from distributed generator to load, apart from supplying reactive power demand, which leads to increase in VA burden, hence its rating. Power angle control method aims at effective utilization of series and shunt APFs through sharing of reactive power to reduce VA burden on shunt APF. Proposed PAC method is based on instantaneous three-phase power estimation technique, which is simple and robust and utilizes already available measurements of UPQCDG. Performance of proposed system is tested in the presence of nonlinear and reactive loads with solar PV generation system. Dynamic performance of system is studied during grid disturbances such as voltage sag and swell, solar irradiation variation, and change in load. Effectiveness of proposed method is validated using real-time simulation performed in Opal-RT, in which electrical circuit of UPQCDG is simulated on FPGA computation engine with submicrosecond time step to emulate real hardware closely.
22
A simple new control technique for unified power quality conditioner (UPQC)
Vinod Khadkikar, Pramod Agarwal, Ambrish Chandra et al. · 2005 · 113 citations