Concepedia

Publication | Closed Access

Time-resolved <i>in situ</i> tomography for the analysis of evolving metal-foam granulates

29

Citations

18

References

2018

Year

Abstract

An experimental setup has been developed that allows for capturing up to 25 tomograms s<sup>-1</sup> using the white X-ray beam at the experimental station EDDI of BESSY II, Berlin, Germany. The key points are the use of a newly developed, precise and fast rotation stage, a very efficient scintillator and a fast CMOS camera. As a first application, the foaming of aluminium alloy granules at 923 K was investigated in situ. Formation and growth of bubbles in the liquid material were observed and found to be influenced by the limited thermal conductivity in the bulk granules. Changes that took place between two tomographic frames separated in time by 39 ms could be detected and analysed quantitatively.