Circulation Cardiovascular Interventions · 2012 · 140 citations · 26 references
MedicineCardiologySurgeryDiagnostic ImagingInterventional CardiologyUltrasonographyCardiovascular ImagingCoronary Artery DiseaseIntravascular ImagingOptical Coherence TomographyPercutaneous Coronary InterventionStent PlacementCoronary Stent DeploymentGuided Coronary InterventionHigh-resolution ImagingImage-guided Percutaneous Coronary InterventionIntracoronary Imaging GuidanceIntravascular Imaging GuidanceStent Apposition AssessmentStent Expansion Assessment
BACKGROUND: Frequency-domain optical coherence tomography (FD-OCT) is a novel, high resolution intravascular imaging modality. Intravascular ultrasound (IVUS) is a widely used conventional imaging modality for achieving optimal stent deployment. The aim of this study was to evaluate the impact of FD-OCT guidance for coronary stent implantation compared with IVUS guidance. METHODS AND RESULTS: A total of 70 patients with de novo coronary artery lesions and either unstable or stable angina pectoris were enrolled in this randomized study (optical coherence tomography [OCT] group: n=35, IVUS group: n=35). In the OCT group, stent implantation was performed under FD-OCT guidance alone and final stent expansion was evaluated by IVUS. In the IVUS group, conventional IVUS guidance was used and final stent apposition was evaluated by FD-OCT. There were no significant differences regarding the procedural, fluoroscopy time, and contrast volume. Although device and clinical success rates also were similar, the visibility of vessel border was significantly lower in the OCT group (P<0.05). Minimum and mean stent area and focal and diffuse stent expansion were smaller (6.1±2.2 mm versus 7.1±2.1 mm, 7.5±2.5 versus 8.7±2.4 mm, 64.7±13.7% versus 80.3±13.4%, 84.2±15.8% versus 98.8±16.5%, P<0.05, respectively), and the frequency of significant residual reference segment stenosis at the proximal edge was higher in the OCT group (P<0.05). Incomplete apposed struts in both groups were similar (P=0.34). CONCLUSIONS: FD-OCT guidance for stent implantation was associated with smaller stent expansion and more frequent significant residual reference segment stenosis compared with conventional IVUS guidance.
26
Pathology of Drug-Eluting Stents in Humans
Michael Joner, Aloke V. Finn, Andrew Farb et al. · Journal of the American College of Cardiology · 2006 · 2.7K citations
Medicine, Cardiology, Pathology +11
Ik‐Kyung Jang, Brett E. Bouma, Dong-Heon Kang et al. · Journal of the American College of Cardiology · 2002 · 1K citations
Final Results of the Can Routine Ultrasound Influence Stent Expansion (CRUISE) Study
Peter J. Fitzgerald, Akio Oshima, Motoya Hayase et al. · Circulation · 2000 · 401 citations
Medicine, Cardiology, Radiology +12