AIP conference proceedings · 2018 · 11 citations · 10 references
EngineeringMaterials EngineeringMechanical EngineeringAir ConditioningHeat TransferThermal AnalysisEvaporative CoolingHeat ConductionThermal DesignThermal Properties Of MaterialsCoolingCooling Pad SystemsEvaporative Cooler PerformanceEvaporative Cooling SystemsMaterial ClassificationPad SystemsThermal-hydraulic PerformanceWater Temperature Regimes
The objective of this study is to evaluate the cooling capacity of evaporative cooling pad system using gunny sack and kerosene stove wick as pad material with variations on water temperature and water discharge of pad material wetting water and its appropriate to the use as an alternative pad material for commercial purpose of CELdek. The variety of pad material that can be used as a cooling medium in evaporative cooling pad system is very wide. Therefore it is need to analyze the performance of alternative pad materials variety in terms of cooling capacity. For this purpose, the test were conducted with three level water discharge (649.98 ml/min; 1299.96 ml/min; 1949.94 ml/min) and three different pad wetting water temperature (10 ± 1°C, 15 ± 1°C; 25 ± 1°C) for each pad material and for the thickness level of pad materials is arranged for gunny sack and kerosene stove wick with the thickness pad level respectively at 0.5; 1.0; 1.5; 2.0; 3.0 mm, in density of 3×2 mm, 2×1 mm and 6.0; 12.0 mm. In this research, 23 cylinder pad with wrapped material pad is arranged in staggered and placed perpendicular to the air flow direction, with length of 75 cm and diameter of 50 mm. The air suction velocity is keep constant on 0.818 m3/s, and discharge water is arranged using water distribution line contained 69 hole, in which for one hole has 28.3 ml/min, therefore to obtain water discharge for the first, second, and third water discharge would has opening hole for respectively 23, 46 and 69 holes,.the experiment is completed for three times repetitions for each discharge water, water temperature of every pad materials. According to the results of this study, it was found that the gunny sack at 3 mm thickness, 1949.94 ml/min water discharge and water temperature 15 ± 1°C has an average temperature drop,ΔT of 4.6°C with cooling capacity of 4.68 kW, while for the kerosene stove wick at 12 mm thickness, 1949.94 ml/min water discharge and water temperature 15 ± 1°C has the average temperature drop,ΔT of 4°C and cooling capacity of 4.0 kW, and it can be stated that the gunny sack has a possibility to consider to be an alternative pad material for CELdek at 1.0 m/s air velocity.
10