ESC Heart Failure · 2018 · 17 citations · 17 references
MedicineCardiologyNuclear MedicineCardiac Nuclear MedicineCardiac TransplantationPulmonologyCardiac CatheterizationChest RadiographyHeart Transplant EvaluationPulmonary AssessmentPulmonary ImagingPulmonary Nuclear ImagingLung Perfusion ImagingLung Perfusion ScansLung Spect QuantificationPulmonary ScintigraphyQuantitative Lung ScintigraphySingle-photon Emission Computed Tomography Perfusion QuantificationVentilation ScintigraphyVentilation-perfusion Scintigraphy
AIMS: Pulmonary congestion remains a diagnostic challenge in patients with heart failure (HF). The recommended method, chest X-ray (CXR), lacks in accuracy, whereas quantitative tomographic lung scintigraphy [ventilation/perfusion single-photon emission computed tomography (V/P SPECT)] has shown promising results but needs independent validation. The aim of this study is to evaluate V/P SPECT as a non-invasive method to assess and quantify pulmonary congestion in HF patients, using right heart catheterization as reference method. The secondary objective was to investigate the performance of V/P SPECT in the clinical setting compared with CXR. METHODS AND RESULTS: Forty-six consecutive patients with HF that were under consideration for heart transplantation were studied prospectively. All participants were examined with V/P SPECT, CXR, and right heart catheterization. Pulmonary artery wedge pressure served as reference method. Quantitative perfusion gradients were derived from V/P SPECT images. Ventilation/perfusion single-photon emission computed tomography images were also assessed both by expert readers and clinical nuclear medicine physicians. Expert readers correctly identified 87% of all patients with an elevated pulmonary artery wedge pressure > 15 mmHg. The average sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for V/P SPECT assessed by the expert readers were 87%, 72%, 85%, and 75%, respectively. In the clinical nuclear medicine setting, V/P SPECT had 87% sensitivity, 63% specificity, 81% PPV, and 71% NPV. Clinically, V/P SPECT outperformed CXR, which had 27% sensitivity, 75% specificity, 67% PPV, and 35% NPV. CONCLUSIONS: Ventilation/perfusion single-photon emission computed tomography can be used as a non-invasive method to diagnose and quantify pulmonary congestion in patients with HF and is more accurate than CXR in diagnosing pulmonary congestion in the clinical setting.
17
John G.F. Cleland, Andrew J.S. Coats, Ewa A. Jankowska et al. · PubMed · 2021 · 19.5K citations
2013 ACCF/AHA Guideline for the Management of Heart Failure
Clyde W. Yancy, Mariell Jessup, Biykem Bozkurt et al. · Journal of the American College of Cardiology · 2013 · 12.6K citations
John J.V. McMurray, Stamatis Adamopoulos, Stefan D. Anker et al. · European Heart Journal · 2012 · 6.9K citations · Full text
Nazzareno Galiè, Marius M. Hoeper, Marc Humbert et al. · European Heart Journal · 2009 · 3.9K citations · Full text