Radiation Oncology · 2018 · 40 citations · 43 references
MedicineOncologyRadiation OncologyClinical Radiation OncologyRadiation DosimetryTreatment PlanningEquivalent DoseRadiation TherapyRadiation ToxicityRadiation Treatment PlanningRadiobiological ModelingThree-dimensional Dose DistributionCervical Cancer RadiotherapyDose Surface MappingDose Volume HistogramDose-volume Histogram AnalysisDose-volume RelationshipDose-volume Toxicity ModelingExternal Beam Radiotherapy DosimetryRectal Toxicity
Better knowledge of the dose-toxicity relationship is essential for safe dose escalation to improve local control in cervical cancer radiotherapy. The conventional dose-toxicity model is based on the dose volume histogram, which is the parameter lacking spatial dose information. To overcome this limit, we explore a comprehensive rectal dose-toxicity model based on both dose volume histogram and dose map features for accurate radiation toxicity prediction. Forty-two cervical cancer patients treated with combined external beam radiotherapy (EBRT) and brachytherapy (BT) were retrospectively studied, including 12 with Grade ≥ 2 rectum toxicity and 30 patients with Grade 0–1 toxicity (non-toxicity patients). The cumulative equivalent 2-Gy rectal surface dose was deformably summed using the deformation vector fields obtained through a recent developed local topology preserved non-rigid point matching algorithm. The cumulative three-dimensional (3D) dose was flattened and mapped to a two-dimensional (2D) plane to obtain the rectum surface dose map (RSDM). The dose volume parameters (DVPs) were calculated from the 3D rectum surface, while the texture features and the dose geometric parameters (DGPs) were extracted from the 2D RSDM. Representative features further computed from DVPs, textures and DGPs by principle component analysis (PCA) and statistical analysis were respectively fed into a support vector machine equipped with a sequential feature selection procedure. The predictive powers of the representative features were compared with the GEC-ESTRO dosimetric parameters D 0.1/1/2cm 3 . Satisfactory predictive accuracy of sensitivity 74.75 and 84.75%, specificity 72.67 and 79.87%, and area under the receiver operating characteristic curve (AUC) 0.82 and 0.91 were respectively achieved by the PCA features and statistical significant features, which were superior to the D 0.1/1/2cm 3 (AUC 0.71). The relative area in dose levels of 64Gy, 67Gy, 68Gy, 87Gy, 88Gy and 89Gy, perimeters in dose levels of 89Gy, as well as two texture features were ranked as the important factors that were closely correlated with rectal toxicity. Our extensive experimental results have demonstrated the feasibility of the proposed scheme. A future large patient cohort study is still needed for model validation.
43
Corinna Cortes, Vladimir Vapnik · Machine Learning · 1995 · 33K citations · Full text
SMOTE: Synthetic Minority Over-sampling Technique
Nitesh V. Chawla, Kevin W. Bowyer, Lawrence Hall et al. · Journal of Artificial Intelligence Research · 2002 · 31.2K citations · Full text
ADASYN: Adaptive synthetic sampling approach for imbalanced learning
Haibo He, Yang Bai, Edwardo A. Garcia et al. · 2008 · 4.4K citations
Richard Pötter, Christine Haie-Méder, Erik Van Limbergen et al. · Radiotherapy and Oncology · 2006 · 1.6K citations
Medicine, Gynecology, Oncology +17