Analysis of Ballast Water Sampling Port Designs Using Computational Fluid Dynamics

R. V. Richard, Jonathan F. Grant, Edward J. Lemieux

Defense Technical Information Center (DTIC) · 2008 · 15 citations · 0 references

Concepts

Abstract

Analytical methods and computational fluid dynamics are used to describe flow conditions encountered at Naval Research Laboratory's Ballast Water Treatment Test Facility. Design tradeoffs are examined in the engineering of sample ports for collecting biological organisms in water samples, and criteria are provided for sample port installation in shipboard piping systems. Results of this work show that the ideal geometry for biological sampling is from the centerline of a straight, vertical, upward-flowing pipe having a sample port diameter between 1.5 and 2.0 times the basic isokinetic diameter as defined in this report. Sample ports should use ball valves for isolation purposes, and diaphragm or venturi valves for flow control; they should be located as close to the overboard outlet as possible; and they should be positioned as far from upstream obstructions and fittings as possible.