OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 1993 · 14 citations · 0 references
EngineeringEnvironmental EngineeringEnvironmental SciencesAir Pollution ControlPollution ControlWaste ManagementAir Pollutant EmissionsCombustion Emission ControlEmissions TestingParticulate MatterVolatile Organic Compound ControlVolatile Organic CompoundsActivated CarbonEmission Performance TestingMercury Emission ControlMercury Emissions ControlMercury RemediationParticulate Matter ControlPowdered Activated CarbonVolatile Organic Compound Removal
EPA conducted a parametric testing project to evaluate the use of powdered activated carbon for removing volatile pollutants from municipal waste combustor (MWC) flue gas. The testing was conducted at the spray dryer absorber/electrostatic precipitator (SD/ESP)-equipped MWC in Camden County, New Jersey. The primary test objectives were to evaluate the effect of carbon type, carbon feed rate, carbon feed method, and ESP operating temperature on emissions of mercury (Hg) and chlorinated dioxins and furans (CDD/CDF), and to assess the impact of carbon injection on the particulate matter control performance of the ESP. Secondary objectives were to examine the impact of carbon injection on emissions of other metals and volatile organic compounds (VOC). The test results indicate that carbon injection upstream of an SD/ESP could achieve high levels (greater than 90%) of Hg and CDD/CDF reduction. Key system operating parameters are carbon feed rate, carbon feed method, and ESP temperature. No detrimental impacts on ESP performance were identified. The study also found that carbon injection does not have a significant impact on emissions of the other metals examined or of VOC.