Journal of Cardiovascular Magnetic Resonance · 2018 · 88 citations · 30 references
MedicineCardiologyNuclear MedicineCardiac Nuclear MedicineDiagnostic ImagingNuclear CardiologyCardiac ImagingCardiac Nuclear ImagingCardiovascular ImagingCoronary Artery ImagingMyocardial Blood Flow QuantificationMyocardial Perfusion ImagingAdenosine Stress ImagingBlood FlowCardiac Myocardial Perfusion ImagingCardiac Pet ImagingMyocardial Flow ReserveMyocardial Perfusion ReserveRepeatability AssessmentRest Myocardial Perfusion Imaging
BACKGROUND: Non-invasive assessment of myocardial ischaemia is a cornerstone of the diagnosis of coronary artery disease. Measurement of myocardial blood flow (MBF) using positron emission tomography (PET) is the current reference standard for non-invasive quantification of myocardial ischaemia. Dynamic myocardial perfusion cardiovascular magnetic resonance (CMR) offers an alternative to PET and a recently developed method with automated inline perfusion mapping has shown good correlation of MBF values between CMR and PET. This study assessed the repeatability of myocardial perfusion mapping by CMR in healthy subjects. METHODS: Forty-two healthy subjects were recruited and underwent adenosine stress and rest perfusion CMR on two visits. Scans were repeated with a minimum interval of 7 days. Intrastudy rest and stress MBF repeatability were assessed with a 15-min interval between acquisitions. Interstudy rest and stress MBF and myocardial perfusion reserve (MPR) were measured for global myocardium and regionally for coronary territories and slices. RESULTS: There was no significant difference in intrastudy repeated global rest MBF (0.65 ± 0.13 ml/g/min vs 0.62 ± 0.12 ml/g/min, p = 0.24, repeatability coefficient (RC) =24%) or stress (2.89 ± 0.56 ml/g/min vs 2.83 ± 0.64 ml/g/min, p = 0.41, RC = 29%) MBF. No significant difference was seen in interstudy repeatability for global rest MBF (0.64 ± 0.13 ml/g/min vs 0.64 ± 0.15 ml/g/min, p = 0.80, RC = 32%), stress MBF (2.71 ± 0.61 ml/g/min vs 2.55 ± 0.57 ml/g/min, p = 0.12, RC = 33%) or MPR (4.24 ± 0.69 vs 3.73 ± 0.76, p = 0.25, RC = 36%). Regional repeatability was good for stress (RC = 30-37%) and rest MBF (RC = 32-36%) but poorer for MPR (RC = 35-43%). Within subject coefficient of variation was 8% for rest and 11% for stress within the same study, and 11% for rest and 12% for stress between studies. CONCLUSIONS: Fully automated, inline, myocardial perfusion mapping by CMR shows good repeatability that is similar to the published PET literature. Both rest and stress MBF show better repeatability than MPR, particularly in regional analysis.
30
Relation between Myocardial Blood Flow and the Severity of Coronary-Artery Stenosis
Neal Uren, Bernard De Bruyne, William Wijns et al. · New England Journal of Medicine · 1994 · 884 citations · Full text
Medicine, Cardiology, Physiology +17
Invasive Assessment of the Coronary Microcirculation
M. Ng, Alan C. Yeung, William F. Fearon · Circulation · 2006 · 404 citations · Full text
Myocardial perfusion reserve: assessment with multisection, quantitative, first-pass MR imaging.
Norbert Wilke, Michael Jerosch‐Herold, Yang Wang et al. · Radiology · 1997 · 388 citations
Medicine, Cardiology, Radiology +17