Microchimica Acta · 2018 · 17 citations · 30 references
Natural SciencesBiochemistryChemistryElectrochemical EngineeringElectrochemistryEnzymologyElectrochemical CellsElectron Transport ChainRedox ChemistryRedox EnzymesRedox ProcessesRedox-active MaterialsElectron TransferElectron Transport Chain ArchitectureIron-sulfur Cluster Electron TransferIron-sulfur Cluster Redox ChemistryMetal-sulfur ClustersMolecular WiresPyrroloquinoline QuinoneRedox Properties
Wiring the active site of an enzyme directly to an electrode is the key to ensuring efficient electron transfer for the proper performance of enzyme-based bioelectronic systems. Iron-sulfur complexes, the first link between proteins and mediating molecules in the biological electron transport chain(s), possess an intrinsic electron transport capability. The authors demonstrate the application of inorganic iron-sulfur clusters (Fe-S) viz. FeS, FeS 2 , Fe 2 S 3, and Fe 3 S 4 , as molecular wires to mediate electron transport between a glucose-selective redox enzyme and the gold electrode. It is shown that Fe-S can emulate the functionality of the natural electron transport chain. Voltammetric studies indicate a significant improvement in electron transport, surface coverage, and resilience achieved by the Fe-S-based glucose anodes when compared to a conventional pyrroloquinoline quinone (PQQ)-based electrode. The Fe-S-based glucose anodes showed glucose oxidation at a potential of +0.5 V vs. Ag/AgCl with Tris-HCl buffer (pH 8) acting as a carrier. The current densities positively correlated with the concentrations of glucose in the range 0.1–100 mM displaying detection limits of 0.77 mM (FeS), 1.22 mM (FeS 2 ), 2.95 mM (Fe 2 S 3 ) , and 14.57 mM (Fe 3 S 4 ). The metal-anchorable sulfur atom, the strong π-coordinating iron atom, the favorable redox properties, low cost, and natural abundance make Fe-S an excellent electron-mediating relay capable of wiring redox active sites to electrode surfaces. Schematic representation of inorganic iron-sulfur clusters used as molecular wires to facilitate direct electron transfer between NAD-glucose dehydrogenase and the gold electrode. The iron-sulfur based glucose anodes improve current response to selectively sense glucose concentrations in the range 0.1–100 mM.
30
DNA-templated assembly and electrode attachment of a conducting silver wire
Erez Braun, Yoav Eichen, Uri Sivan et al. · Nature · 1998 · 2.4K citations
"Plugging into Enzymes": Nanowiring of Redox Enzymes by a Gold Nanoparticle
Yi Xiao, Fernando Patolsky, Eugenii Katz et al. · Science · 2003 · 1.3K citations
Towards molecular electronics with large-area molecular junctions
Hylke B. Akkerman, Paul W. M. Blom, Dago M. de Leeuw et al. · Nature · 2006 · 623 citations · Full text