Physics in Medicine and Biology · 2018 · 25 citations · 50 references
Natural SciencesRadiologyAcousticsUltrasonographyUltrasoundAcoustic ImagingThree-dimensional UltrasoundUltrasonicsUltrasound ImagingUltrasound PhysicsVertebral AnatomyIntervertebral ForamenRay AcousticsRay Tracing AcousticsRay-based TomographyTransducer CharacterizationTransducer SimulationUltrasound Computed TomographyVertebral Canal Anatomy
The simulation accuracy of transvertebral ultrasound propagation using a multi-layered ray acoustics model based on CT-derived vertebral geometry was investigated through comparison with experimental measurements of pressure fields in ex vivo human vertebral foramen. A spherically focused transducer (5 cm diameter, f-number 1.2, 514 kHz) was geometrically focused to the centre of individual thoracic vertebral foramen, through the posterior bony elements. Transducer propagation paths through the laminae and the spinous processes were tested. Simulation transducer-vertebra configurations were registered to experiment transducer-vertebra configurations, and simulation accuracy of the simulation model was evaluated for predicting maximum transmitted pressure to the canal, voxel pressure in the canal, and focal distortion. Accuracy in predicting maximum transmitted pressure was calculated by vertebra, and it is shown that simulation predicts maximum pressure with a greater degree of accuracy than a vertebra-specific insertion loss. Simulation error in voxel pressure was evaluated using root-mean-square error and cross-correlation, and found to be similar to the water-only case. Simulation accuracy in predicting focal distortion was evaluated by comparing experiment and simulation maximum pressure location and weighted >50% focal volume location. Average simulation error across all measurements and simulations in maximum pressure location and weighted >50% focal volume location were 2.3 mm and 1.5 mm, respectively. These errors are small relative to the dimensions of the transducer focus (4.9 mm full width half maximum), the spinal cord (10 mm diameter), and vertebral canal diameter (15-20 mm diameter). These results suggest that ray acoustics can be applied to simulating transvertebral ultrasound propagation.
50
A Randomized Trial of Focused Ultrasound Thalamotomy for Essential Tremor
W. Jeffrey Elias, Nir Lipsman, William G. Ondo et al. · New England Journal of Medicine · 2016 · 1.1K citations · Full text
Acoustical properties of the human skull
F. J. Fry, James E. Barger · The Journal of the Acoustical Society of America · 1978 · 615 citations
Natural Sciences, Anatomy, Physics +15