BMC Anesthesiology · 2018 · 32 citations · 39 references
MedicineAnesthesiologySurgeryAnesthesiaAnesthetic TechniquesGeneral AnesthesiaGeneral Anesthetic AgentsIntracranial Pressure ManagementIncreased Intracranial PressureOptic Nerve Sheath Diameter MeasurementOptic Nerve Sheath Diameter MonitoringPropofol AnesthesiaPropofol UseSevoflurane AnesthesiaSurgical Field ExposureSurgical Site Exposure
BACKGROUND: Robot-assisted laparoscopic prostatectomy (RALP) requires pneumoperitoneum and the Trendelenburg position to optimize surgical exposure, which can increase intracranial pressure (ICP). Anesthetic agents also influence ICP. We compared the effects of propofol and sevoflurane on sonographic optic nerve sheath diameter (ONSD) as a surrogate for ICP in prostate cancer patients who underwent RALP. METHODS: Thirty-six patients were randomly allocated to groups receiving propofol (propofol group, n = 18) or sevoflurane (sevoflurane group, n = 18) anesthesia. The ONSD was measured 10 min after induction of anesthesia in the supine position (T1); 5 min (T2), 30 min (T3), and 60 min (T4) after establishing pneumoperitoneum and the Trendelenburg position; and at the end of surgery after desufflation in the supine position (T5). Respiratory and hemodynamic variables were also evaluated. RESULTS: The ONSD was significantly different between the propofol group and the sevoflurane group at T4 (5.27 ± 0.35 mm vs. 5.57 ± 0.28 mm, P = 0.007), but not at other time points. The ONSDs at T2, T3, T4, and T5 were significantly greater than at T1 in both groups (all P < 0.001). Arterial carbon dioxide partial pressure, arterial oxygen partial pressure, peak airway pressure, plateau airway pressure, systolic blood pressure, pulse pressure variation, body temperature and regional cerebral oxygen saturation, except heart rate, were not significantly different between the two groups. CONCLUSIONS: The ONSD was significantly lower during propofol anesthesia than during sevoflurane anesthesia 60 min after pneumoperitoneum and the Trendelenburg position, suggesting that propofol anesthesia may help minimize ICP changes in robotic prostatectomy patients. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT03271502 . Registered August 31, 2017.
39
Influence of Age and Gender on the Pharmacokinetics and Pharmacodynamics of Remifentanil
Charles F. Minto, Thomas W. Schnider, Talmage D. Egan et al. · Anesthesiology · 1997 · 1.2K citations · Full text
PHARMACOKINETIC MODEL DRIVEN INFUSION OF PROPOFOL IN CHILDREN
Bret Marsh, Martin White, N S Morton et al. · British Journal of Anaesthesia · 1991 · 1.2K citations · Full text
Robotically‐assisted laparoscopic radical prostatectomy
J. Binder, Wolfgang Kramer · British Journal of Urology · 2001 · 749 citations