<em>In Vivo</em> Electrophysiological Measurement of Compound Muscle Action Potential from the Forelimbs in Mouse Models of Motor Neuron Degeneration

Eveliina Pollari, Robert Prior, Wim Robberecht, Philip Van Damme, Ludo Van Den Bosch

Journal of Visualized Experiments · 2018 · 38 citations · 16 references

DOIFull text

Open access

Concepts

Abstract

Assessing the functionality of the nerve axon provides detailed information on the progression of neuromuscular disorders. Electrophysiological recordings provide a sensitive approach to measure nerve conduction in humans and rodent models. To broaden the technical possibilities for electromyography in mice, the measurement of compound muscle action potentials (CMAPs) from the brachial plexus nerve in the forelimb using needle electrodes is described here. CMAP recordings after stimulating the sciatic nerve in hindlimbs have been previously described. The newly introduced method here allows for the evaluation of the nerve conductivity at an additional site, and thus provides a more profound overview of the neuromuscular functionality. The technique provides information on both the relative number of functional axons and the myelination level. Thereby, this method can be applied to assess both axonal diseases as well as demyelinating conditions. This minimally invasive method does not require extraction of the nerve and therefore it is suitable for repeated measurements for longitudinal follow-up in the same animal. Similar recordings are performed in clinical setups to emphasize the translational relevance of the method.

References

16