Prospective Comparison of FFR Derived From Coronary CT Angiography With SPECT Perfusion Imaging in Stable Coronary Artery Disease

Niels Peter Rønnow Sand, Karsten Tange Veien, Søren Nielsen, Bjarne Linde Nørgaard, Pia Veldt Larsen, Allan Johansen, Søren Hess, Lone K Deibjerg, Majed Husain, Anders Junker,

JACC. Cardiovascular imaging · 2018 · 110 citations · 27 references

DOIFull text

Open access

Concepts

Abstract

OBJECTIVES: ) with that of single-photon emission computed tomography (SPECT), using a fractional flow reserve (FFR) value of ≤0.80 as the reference for diagnosing at least 1 hemodynamically significant stenosis in a head-to-head comparison of patients with intermediate coronary stenosis as determined by coronary CTA. BACKGROUND: and myocardial perfusion imaging by SPECT in symptomatic patients with intermediate range coronary artery disease (CAD). METHODS: ≤0.80 distally in at least 1 coronary artery with a diameter ≥2 mm classified patients as having ischemia. Ischemia by SPECT was encountered if a reversible perfusion defect (summed difference score ≥2) or transitory ischemic dilation of the left ventricle (ratio >1.19) were found. RESULTS: versus SPECT, were sensitivity of 91% (95% CI: 81% to 97%) versus 41% (95% CI: 29% to 55%; p < 0.001); specificity of 55% (95% CI: 44% to 66%) versus 86% (95% CI: 77% to 93%; p < 0.001); negative predictive value of 90% (95% CI: 82% to 98%) versus 68% (95% CI: 59% to 77%; p = 0.001); positive predictive value of 58% (95% CI: 48% to 68%) versus 67% (95% CI: 51% to 82%; p = NS); and accuracy of 70% (95% CI: 62% to 77%) versus 68% (95% CI: 60% to 75%; p = NS) respectively. CONCLUSIONS: demonstrated a significantly higher diagnostic sensitivity than SPECT.

References

27