In quality assessment of umbilical and uterine artery pulsed-wave Doppler measurements, our proposed objective six-point image-scoring system is associated with greater reproducibility than is subjective assessment. We recommend this as the preferred method for quality control, auditing and teaching. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.