Pacing and Clinical Electrophysiology · 2018 · 14 citations · 11 references
MedicineCardiologyInternal MedicineClinical Decision SupportCost-effectiveness AnalysisHealth Technology AssessmentCardiac AssessmentCardiac Risk AssessmentCardiovascular MonitoringHeart FailureImplantable Cardioverter-defibrillator CareCardiac Implantable DevicesCardiac Outcome AssessmentCardiac Sensing DevicesClinical Event DetectionHeart Failure Risk PredictionImplantable Cardioverter DefibrillatorsPositive Predictive ValueVentricular Ejection Fraction Assessment
BACKGROUND: Heart failure (HF) hospitalizations have a negative impact on quality of life and imply important costs. Intrathoracic impedance (ITI) variations detected by cardiac devices have been hypothesized to predict HF hospitalizations. Although Optivol™ algorithm (Medtronic, Minneapolis, MN, USA) has been widely studied, CorVue™ algorithm's (St. Jude Medical, St. Paul, MN, USA) long-term efficacy has not been systematically evaluated in a "real-life" cohort. METHODS: CorVue™ was activated in implantable cardioverter defibrillator (ICD)/cardiac resynchronization therapy defibrillator (CRT-D) patients to store information about ITI measures. Clinical events (new episodes of HF requiring treatment and hospitalizations) and CorVue™ data were recorded every 3 months. Appropriate CorVue™ detection for HF was considered if it occurred in the 4 prior weeks to the clinical event. RESULTS: Fifty-three ICD/CRT-D (26 ICD and 27 CRT-D) patients (67 ± 1 years old, 79% male) were included. Device position was subcutaneous in 28 patients. At inclusion, mean left ventricular ejection fraction was 25 ± 7% and 27 patients (51%) were in New York Heart Association class I, 18 (34%) in class II, and eight (15%) in class III. After a mean follow-up of 17 ± 9 months, 105 ITI drops alarms were detected in 32 patients (60%). Only six alarms were appropriate (true positive) and required hospitalization. Eighteen patients (34%) presented 25 clinical episodes (12 hospitalizations and 13 emergency room/ambulatory treatment modifications). Nineteen of these clinical episodes (76%) remained undetected by the CorVue™ (false negative). Sensitivity of CorVue™ resulted in 24%, specificity was 70%, positive predictive value of 6%, and negative predictive value of 93%. CONCLUSIONS: CorVue™ showed a low sensitivity to predict HF events. Therefore, routinely activation of this algorithm could generate misleading information.
11
Intrathoracic Impedance Monitoring in Patients With Heart Failure
Cheuk‐Man Yu, Li Wang, Elaine Chau et al. · Circulation · 2005 · 711 citations · Full text
Viviane M. Conraads, Luigi Tavazzi, Massimo Santini et al. · European Heart Journal · 2011 · 295 citations · Full text
William T. Abraham, Steven J. Compton, Garrie J. Haas et al. · Congestive Heart Failure · 2011 · 227 citations · Full text