Optometry and Vision Science · 2018 · 23 citations · 16 references
Health ProfessionsOphthalmologySurgeryClinical OptometryContact Lens PracticeOphthalmic SurgeryAstigmatism CorrectionContact Lens Clinical PracticeContact Lens FittingContact Lens InterventionsKeratoconus Lens FittingScleral LensesAstigmatismManagement Of Irregular AstigmatismMini-scleral Lens FittingMini-scleral LensesResidual AstigmatismScleral Lens DesignScleral Lens EvaluationScleral Lens Vision Correction
SIGNIFICANCE: New bitangential mini-scleral lens designs provide a highly precise fit, follow the scleral shape, are comfortable to wear, and can correct residual astigmatism. This new scleral lens design complements the arsenal of medical contact lenses available to eye care practitioners. PURPOSE: The aim of this study was to evaluate the subjective and objective performance of a new mini-scleral lens design with a bitangential periphery. METHODS: In this observational study, data were collected for up to 15 months (median, 84 days; interquartile range, 76 days) from the left eyes of 133 patients fitted with this newly designed lens. Data were recorded during regular visits at Visser Contact Lens Practice's scleral lens clinics: diagnosis, clinical indication for scleral lenses, previous contact lens type, subjective performance, horizontal visible iris diameter, corrected distance visual acuity, and scleral lens fitting characteristics. RESULTS: The most common indication was keratoconus (45%), followed by irregular astigmatism (22%), keratoplasty (16.5%), ocular surface disease (13.5%), and other forms of irregular astigmatism (3%). The majority of patients (79%) scored comfort as either a 4 or 5 (out of 5), and 82% wore their lenses 12 hours or longer a day. Most lenses (81%) had a diameter of 16 mm (median, 16 mm; range, 15.5 to 17 mm) and were composed of Boston XO2 (46%), Menicon Z (44%), Boston XO (9%), or Boston Equalens II (1%). The median corrected distance visual acuity was 0.022 logarithm of the minimal angle of resolution (interquartile range, 0.155). The fitting characteristics revealed optimal values for centration and movement in 91% and 83%, respectively. Finally, the median stabilization axis was 50 degrees. CONCLUSIONS: New mini-scleral lenses with bitangential peripheral geometry yield satisfactory clinical results and good subjective performance and are therefore an effective option for managing patients who have irregular astigmatism or other corneal pathology.
16
Gas-permeable scleral contact lens therapy in ocular surface disease
Tatiana Romero-Rangel, Panagiota Stavrou, Janis Cotter et al. · American Journal of Ophthalmology · 2000 · 265 citations
Medicine, Ophthalmology, Surgery +14
Kenneth W. Pullum, Mark Whiting, Roger Buckley · Cornea · 2005 · 199 citations
Medicine, Ophthalmology, Surgery +15
Predicting estimates of oxygen transmissibility for scleral lenses
Langis Michaud, Eef van der Worp, Daniel Brazeau et al. · Contact Lens and Anterior Eye · 2012 · 165 citations
Scleral Contact Lenses May Help Where Other Modalities Fail
Ori Segal, Yaniv Barkana, Dafna Hourovitz et al. · Cornea · 2003 · 143 citations
Medicine, Ophthalmology, Surgery +15
Modern Scleral Lenses Part I: Clinical Features
Esther-Simone Visser, Rients Visser, Henk J.J. van Lier et al. · Eye & Contact Lens Science & Clinical Practice · 2007 · 130 citations
Medicine, Ophthalmology, Surgery +17