Review of Scientific Instruments · 2018 · 28 citations · 27 references
EngineeringNuclear EngineeringNuclear InstrumentationPlasma PhysicsRadiation PhysicsAccelerator PhysicsAccelerator ShieldingBeam Acceleration SystemsBeam Extraction SystemsBeam InjectorsBeam TransportInjector DesignIon Source PhysicsIon SourcesNuclear Spallation
The Spallation Neutron Source operates reliably at 1.2 MW and will gradually ramp to 1.4 MW. This paper briefly recalls some of the struggles when the unprecedented project was started and ramped to 1 MW over a 3½ year period. This was challenging, especially for the H− ion source and the low-energy beam transport system, which make up the H− injector. It took several more years to push the H− injector to the 1.4 MW requirements, and even longer to reach close to 100% injector availability. An additional breakthrough was the carefully staged, successful extension of the H− source service cycle so that disruptive source changes became rare events. More than 7 A·h of extracted H− ions have been demonstrated with a single source without maintenance, more than twice the single-source quantity of ions produced by any other high-current H− accelerator facility. Achieving the 1.4 MW requirements with close to 100% availability and record-breaking source service cycles were the basis for the 2017 Brightness Award.
27
Negative hydrogen ion production mechanisms
M. Bacal, M. Wada · Applied Physics Reviews · 2015 · 280 citations