Environmental and Climate Technologies · 2018 · 18 citations · 16 references
ArchitectureArchitectural EngineeringMaterials EngineeringBuilding MaterialsBuilding Performance SimulationHeat TransferBuilding Thermal PerformanceHygrothermal PerformanceInsulation MaterialsMasonry MaterialsMaterial PerformanceThermal PerformanceBrick MasonryBrick Masonry WallsHygrothermal ModelingHygrothermal ResponseHygrothermal SimulationInsulating MaterialsMasonry Hygrothermal BehaviorMineral Wool Insulation
Abstract Being an important contributor to the final energy consumption, historic buildings built before 1945 have high specific heating energy consumption compared to current energy standards and norms. However, they often cannot be insulated from the outside due to their heritage and culture value. Internal insulation is an alternative. However internal insulation faces challenges related to hygrothermal behaviour leading to mold growth, freezing, deterioration and other risks. The goal of this research is to link hygrothermal simulation results with experimental results for internally insulated historic brick masonry to assess correlation between simulated and measured data as well as the most influential parameters. The study is carried out by both a mathematical simulation tool and laboratory tests of historic masonry with internal insulation with four insulation materials (mineral wool, EPS, wood fiber and granulated aerogel) in a cold climate (average 4000 heating degree days). We found disparity between measured and simulated hygrothermal performance of studied constructions due to differences in material parameters and initial conditions of materials. The latter plays a more important role than material parameters. Under a steady state of conditions, the condensate tolerating system varies between 72.7 % and 80.5 % relative humidity, but in condensate limiting systems relative humidity variates between 73.3 % and 82.3 %. The temperature between the masonry wall and all insulation materials has stabilized on average at +10 °C. Mold corresponding to Mold index 3 was discovered on wood fiber mat.
16
Existing building retrofits: Methodology and state-of-the-art
Zhenjun Ma, Paul Cooper, Daniel Daly et al. · Energy and Buildings · 2012 · 1.2K citations
Architecture, Architectural Engineering, Building Science +10
Moisture and Bio-deterioration Risk of Building Materials and Structures
Hannu Viitanen, Juha Vinha, Kati Salminen et al. · Journal of Building Physics · 2009 · 339 citations · Full text