Concepedia

Publication | Closed Access

Development and Validation of an Ultra-Performance Liquid Chromatography–Tandem Mass Spectrometry Method for the Concurrent Measurement of Gabapentin, Lamotrigine, Levetiracetam, Monohydroxy Derivative of Oxcarbazepine, and Zonisamide Concentrations in Serum in a Clinical Setting

30

Citations

13

References

2018

Year

Abstract

A simple, cost-effective, and robust ultra-performance liquid chromatography-tandem mass spectrometry method for monitoring multiple AEDs was developed and validated to address the clinical needs of patients at our institution.