Journal of Cardiopulmonary Rehabilitation and Prevention · 2018 · 19 citations · 29 references
MedicineRehabilitation MedicineExercise TestingPulmonary RehabilitationPulmonologyCardiopulmonary Exercise TestingExercise Pulmonary Function TestingExercise TrainingFunctional Capacity AssessmentInterstitial Lung Disease RehabilitationPulmonary Assessment6-Minute Walk TestCross-sectional Correlation StudyExercise Test ReliabilityExercise Test ValidityIncremental Shuttle Walk TestInterstitial Lung Disease AssessmentLongitudinal Correlation StudyPulmonary Rehabilitation For Dyspnea
PURPOSE: To determine the reliability, validity, and responsiveness of the incremental shuttle walk test (ISWT) in patients with interstitial lung disease (ILD). METHODS: This was a cross-sectional longitudinal study. Patients (n = 27, 10 males; mean age ± SD, 61 ± 9.8 y) with ILD of any etiology, who participated in an outpatient pulmonary rehabilitation (PR) program, were recruited. Reliability was determined by comparing the distance covered in meters between the ISWT-1 and the ISWT-2. Validity was assessed by correlating the distance covered in the ISWT-1, with the maximum oxygen consumption ((Equation is included in full-text article.)O2max) obtained through cardiopulmonary exercise testing and distance covered during the 6-min walk test (6MWT). Responsiveness was assessed by comparing the distance covered in the ISWT-3, undertaken after the completion of PR, to the ISWT-1. RESULTS: The distance covered was equivalent between the ISWT-1 (216.7 ± 64.9 m) and the ISWT-2 (220.7 ± 67.3 m), with an excellent intraclass correlation coefficient (ICC2,1 = 0.91; 95% CI, 0.81-0.95). The standard error of measurement and minimal detectable change at the 95% CI (MDC95) values for the ISWT were 19.5 m and 53.9m, respectively. There were significant correlations between the distance covered on the ISWT and (Equation is included in full-text article.)O2max (r = 0.79, P < .0001) and the distance covered on the 6MWT (r = 0.76, P < .0001). Following PR, the change in the ISWT distance showed large effect size (ES = 0.85) and standardized response mean (SRM = 1.58). CONCLUSIONS: The ISWT is a reliable, valid, and responsive measure of estimated functional capacity in patients with ILD.
29
Martin R. Miller, J. Hankinson, Vito Brusasco et al. · European Respiratory Journal · 2005 · 15.7K citations · Full text
Ganesh Raghu, Harold R. Collard, Jim Egan et al. · American Journal of Respiratory and Critical Care Medicine · 2011 · 7.3K citations · Full text