Critical Care · 2018 · 100 citations · 21 references
MedicineSurgeryRenal Replacement TherapyVentilationVentilator ManagementAcute Respiratory Distress SyndromeExtracorporeal Life SupportExtracorporeal Membrane OxygenationLung-protective VentilationMechanical VentilationVentilatory SupportDriving Pressure MinimizationLung-protective Ventilation ModesPlateau Pressure AssessmentPlateau Pressure LimitationPlateau Pressure TargetsRenal Support During Extracorporeal Membrane OxygenationVentilator-associated Lung InjuryVentilator-induced Lung Injury
Extracorporeal carbon-dioxide removal (ECCO 2 R) might allow ultraprotective mechanical ventilation with lower tidal volume (VT) (< 6 ml/kg predicted body weight), plateau pressure (P plat ) (< 30 cmH 2 O), and driving pressure to limit ventilator-induced lung injury. This study was undertaken to assess the feasibility and safety of ECCO 2 R managed with a renal replacement therapy (RRT) platform to enable very low tidal volume ventilation of patients with mild-to-moderate acute respiratory distress syndrome (ARDS). Twenty patients with mild ( n = 8) or moderate ( n = 12) ARDS were included. VT was gradually lowered from 6 to 5, 4.5, and 4 ml/kg, and PEEP adjusted to reach 23 ≤ P plat ≤ 25 cmH 2 O. Standalone ECCO 2 R (no hemofilter associated with the RRT platform) was initiated when arterial PaCO 2 increased by > 20% from its initial value. Ventilation parameters (VT, respiratory rate, PEEP), respiratory system compliance, P plat and driving pressure, arterial blood gases, and ECCO 2 R-system operational characteristics were collected during at least 24 h of very low tidal volume ventilation. Complications, day-28 mortality, need for adjuvant therapies, and data on weaning off ECCO 2 R and mechanical ventilation were also recorded. While VT was reduced from 6 to 4 ml/kg and P plat kept < 25 cmH 2 O, PEEP was significantly increased from 13.4 ± 3.6 cmH 2 O at baseline to 15.0 ± 3.4 cmH 2 O, and the driving pressure was significantly reduced from 13.0 ± 4.8 to 7.9 ± 3.2 cmH 2 O (both p < 0.05). The PaO 2 /FiO 2 ratio and respiratory-system compliance were not modified after VT reduction. Mild respiratory acidosis occurred, with mean PaCO 2 increasing from 43 ± 8 to 53 ± 9 mmHg and mean pH decreasing from 7.39 ± 0.1 to 7.32 ± 0.10 from baseline to 4 ml/kg VT, while the respiratory rate was not altered. Mean extracorporeal blood flow, sweep-gas flow, and CO 2 removal were 421 ± 40 ml/min, 10 ± 0.3 L/min, and 51 ± 26 ml/min, respectively. Mean treatment duration was 31 ± 22 h. Day-28 mortality was 15%. A low-flow ECCO 2 R device managed with an RRT platform easily and safely enabled very low tidal volume ventilation with moderate increase in PaCO 2 in patients with mild-to-moderate ARDS. ClinicalTrials.gov, NCT02606240. Registered on 17 November 2015.
21