Review of Scientific Instruments · 2018 · 19 citations · 11 references
Natural SciencesElectrical EngineeringPhysicsOpticsOptoelectronicsPhotonicsDetector TechnologyLidar Remote SensingLidar Data AcquisitionLidar InstrumentationLidar SensingLidar SensorsLidar SystemsPhosphor Screen SensitivityPower GainTemporal Pulse Distortion
The streak tubes with a large effective photocathode area, large effective phosphor screen area, and high photocathode radiant sensitivity are essential for improving the field of view, depth of field, and detectable range of the multiple-slit streak tube imaging lidar. In this paper, a high spatial resolution, large photocathode area, and compact meshless streak tube with a spherically curved cathode and screen is designed and tested. Its spatial resolution reaches 20 lp/mm over the entire Φ28 mm photocathode working area, and the simulated physical temporal resolution is better than 30 ps. The temporal distortion in our large-format streak tube, which is shown to be a non-negligible factor, has a minimum value as the radius of curvature of the photocathode varies. Furthermore, the photocathode radiant sensitivity and radiant power gain reach 41 mA/W and 18.4 at the wavelength of 550 nm, respectively. Most importantly, the external dimensions of our streak tube are no more than Φ60 mm × 110 mm.
11
Design and modeling of three-dimensional laser imaging system based on streak tube
Wenze Xia, Shaokun Han, Naeem Ullah et al. · Applied Optics · 2017 · 27 citations
Range accuracy analysis of streak tube imaging lidar systems
Guangchao Ye, Rongwei Fan, Zhaodong Chen et al. · Optics Communications · 2015 · 25 citations