RSC Advances · 2018 · 26 citations · 28 references
EngineeringChemical EngineeringEnvironmental EngineeringElectrochemical EngineeringElectrochemistryWater TreatmentAnaerobic DigestionBioelectrochemical SystemsElectrochemical CellsElectrolysis ProcessesCarbon ElectrodesChemical Oxygen DemandGranular Activated CarbonInternal ResistanceLong-term PerformanceMicrobial Electrochemical TechnologiesMicrobial Electrolysis CellsRemoval Efficiency
at a frequency of 0.1-0.5 Hz and a duty cycle of 90-95%. To evaluate the impact of such periodic power supply disconnection (on/off mode) on MEC performance, experiments were carried out in two flow-through MECs with activated granular carbon electrodes. The on/off operating strategy was applied to one MEC, while the other one was operated at a fixed voltage (control MEC). Long-term on/off operation resulted in progressive increase in COD removal efficiency (from 80% to 90%) and MEC current over time, while the control MEC showed stable but inferior performance. Furthermore, by changing the operating strategies and applying the on/off approach to the control MEC, its COD removal was increased from 78% to 83% and internal resistance decreased. The proposed on/off mode of operation can be used to develop a high-rate MEC-based wastewater treatment system.
28
Hydrogen Production with a Microbial Biocathode
René A. Rozendal, Adriaan W. Jeremiasse, H.V.M. Hamelers et al. · Environmental Science & Technology · 2007 · 506 citations