Journal of Applied Clinical Medical Physics · 2018 · 18 citations · 24 references
MedicineOncologyRadiation OncologyBreast OncologyRadiation DosimetryTreatment PlanningBreast Cancer RadiotherapyDose CalculationRadiation TherapyRadiation Treatment PlanningRegional Nodal IrradiationTreatment Planning Dose CalculationAnisotropic Analytical AlgorithmsBreast Dose CalculationClinical Target Volume CoverageDose Calculation SoftwarePlan Quality AssessmentPlan Quality MetricsRadiotherapy Dose PlanningTreatment Planning Dosimetry
Abstract Purpose Two dose calculation algorithms are available in Varian Eclipse software: Anisotropic Analytical Algorithm ( AAA ) and Acuros External Beam ( AXB ). Many Varian Eclipse‐based centers have access to AXB ; however, a thorough understanding of how it will affect plan characteristics and, subsequently, clinical practice is necessary prior to implementation. We characterized the difference in breast plan quality between AXB and AAA for dissemination to clinicians during implementation. Methods Locoregional irradiation plans were created with AAA for 30 breast cancer patients with a prescription dose of 50 Gy to the breast and 45 Gy to the regional node, in 25 fractions. The internal mammary chain ( IMC CTV ) nodes were covered by 80% of the breast dose. AXB , both dose‐to‐water and dose‐to‐medium reporting, was used to recalculate plans while maintaining constant monitor units. Target coverage and organ‐at‐risk doses were compared between the two algorithms using dose–volume parameters. An analysis to assess location‐specific changes was performed by dividing the breast into nine subvolumes in the superior–inferior and left–right directions. Results There were minimal differences found between the AXB and AAA calculated plans. The median difference between AXB and AAA for breast CTV V 95% , was <2.5%. For IMC CTV , the median differences V 95% , and V 80% were <5% and 0%, respectively; indicating IMC CTV coverage only decreased when marginally covered. Mean superficial dose increased by a median of 3.2 Gy. In the subvolume analysis, the medial subvolumes were “hotter” when recalculated with AXB and the lateral subvolumes “cooler” with AXB ; however, all differences were within 2 Gy. Conclusion We observed minimal difference in magnitude and spatial distribution of dose when comparing the two algorithms. The largest observable differences occurred in superficial dose regions. Therefore, clinical implementation of AXB from AAA for breast radiotherapy is not expected to result in changes in clinical practice for prescribing or planning breast radiotherapy.
24
Regional Nodal Irradiation in Early-Stage Breast Cancer
Timothy J. Whelan, Ivo A. Olivotto, Wendy R. Parulekar et al. · New England Journal of Medicine · 2015 · 1.3K citations · Full text