IEEE Journal of Translational Engineering in Health and Medicine · 2018 · 124 citations · 31 references
EngineeringBiomedical EngineeringPhysiologyBioinstrumentationBiomedical Signal ProcessingPsychophysiologyColor PerceptionRespiratory Signal AnalysisVital SignsVital Signs AssessmentVital Signs RecordingWearable Health TechnologiesHeart RatePhotoplethysmogram Signal ProcessingPhotoplethysmographyPhysiological SensingPhysiological Signal MonitoringPhysiological Signal ProcessingRespiratory RateRespiratory Rate Monitoring
. In this pilot study, we have introduced a novel iPPG method where by measuring variations in color of reflected light, i.e., Hue, and can therefore measure both HR and respiratory rate (RR) from the video of a subject's face. This paper was performed on 25 healthy individuals (Ages 20-30, 15 males and 10 females, and skin color was Fitzpatrick scale 1-6). For each subject we took two 20 second video of the subject's face with minimal movement, one with flash ON and one with flash OFF. While recording the videos we simultaneously measuring HR using a Biosync B-50DL Finger Heart Rate Monitor, and RR using self-reporting. This paper shows that our proposed approach of measuring iPPG using Hue (range 0-0.1) gives more accurate readings than the Green channel. HR/Hue (range 0-0.1) ([Formula: see text], [Formula: see text]-value = 4.1617, and RMSE = 0.8887) is more accurate compared with HR/Green ([Formula: see text], [Formula: see text]-value = 11.60172, and RMSE = 0.9068). RR/Hue (range 0-0.1) ([Formula: see text], [Formula: see text]-value = 0.2885, and RMSE = 3.8884) is more accurate compared with RR/Green ([Formula: see text], [Formula: see text]-value = 0.5608, and RMSE = 5.6885). We hope that this hardware agnostic approach for detection of vital signals will have a huge potential impact in telemedicine, and can be used to tackle challenges, such as continuous non-contact monitoring of neo-natal and elderly patients. An implementation of the algorithm can be found at https://pulser.thinkbiosolution.com.
31
World Medical Association Declaration of Helsinki
JAMA · 2013 · 29.4K citations
Rapid object detection using a boosted cascade of simple features
Paul Viola, Michael Jones · 2005 · 18.2K citations
Task Force of the European Society of Cardiology the North A Electrophysiology · Circulation · 1996 · 16.9K citations
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Marek Malik, J. Thomas Bigger, A. John Camm et al. · European Heart Journal · 1996 · 15.3K citations · Full text
Nursing, Cardiology, Physiology +15
Remote plethysmographic imaging using ambient light
Wim Verkruysse, Lars O. Svaasand, J. Stuart Nelson · Optics Express · 2008 · 1.7K citations · Full text