Concepedia

Publication | Open Access

Evaluation of a Hollow-Fiber Liquid-Phase Microextraction Technique for the Simultaneous Determination of PPI Drugs in Human Plasma by LC-DAD

12

Citations

34

References

2018

Year

Abstract

This study involved the development, validation and application of a three-phase hollow-fiber liquid-phase microextraction (HF-LPME) and liquid chromatography with diode array detection (LC-DAD) method for the simultaneous determination of the proton pump inhibitor (PPI) drugs omeprazole, pantoprazole and lansoprazole in human plasma. The evaluation of the HF-LPME parameters was crucial for the determination of the drugs and the conditions selected were: 1-octanol as solvent; phosphate buffer at pH 5 as donor phase; borate buffer at pH 10 as acceptor phase; extraction time of 15 min; stirring at 750 rpm and NaCl was added at 5% (w/v). Validation of the method according to US-FDA recommendations showed a good linear range (0.2-2.0 μg/mL) for all analytes, with a determination coefficient >0.9910. Precision was evaluated using intra- and inter-day assays, which showed relative standard deviations (RSD), <15% for all concentrations, with a limit of quantification (LOQ) of 0.2 μg/mL. Accuracy was also assessed at these concentration levels and was in the range from 80 to 130%. Finally, the sensitive, selective and reproducible HF-LPME/LC-DAD developed method was successfully applied to human plasma samples from patients undergoing therapy with the PPI drugs.

References

YearCitations

Page 1