Experimental behavior of strengthening of masonry infilled reinforced concrete frames by adding rebar‐reinforced stucco

Fatih Kaya, Hamide Tekeli

Structural Concrete · 2018 · 22 citations · 17 references

Concepts

TL;DR

Strengthening masonry infill walls in reinforced concrete buildings has become a focus of recent research, with steel mesh, additional mortar layers, fiber‑reinforced polymers, and prefabricated panels emerging as leading techniques. This study experimentally evaluates a cost‑effective, mold‑free strengthening method that uses steel reinforcing mesh and a mortar layer on RC frames with masonry infill walls. Eleven one‑third‑scale, one‑bay, one‑story non‑ductile RC frames with masonry infill—featuring low‑compressive concrete, insufficient stirrups, and a strong beam relative to the column—were constructed and subjected to repeated seismic loading, varying anchorage length, spacing, configuration, and placement of the added layer inside or outside the wall. The tests revealed load–displacement behavior, initial stiffness, displacement ductility, and energy dissipation characteristics, which were analyzed to assess the strengthening effectiveness.

Abstract

Strengthening of structures may become a necessity to overcome the mistakes made during the design and construction phases of existing reinforced concrete (RC) buildings. In recent years, researches have been intensified on the economical and easy application of the strengthening of masonry infill walls in RC buildings. Strengthening of masonry infill wall with steel reinforcing mesh and additional mortar layer, fiber reinforced polymers and prefabricated concrete panels have become in the forefront of these techniques. In this study, the RC frame infilled with masonry walls and strengthened with steel reinforcing mesh and mortar layer was examined experimentally. One of the most important reasons for choosing this method is that the strengthening could be achieved with less cost, workmanship and without the need to prepare molds for reinforcement. The main variables that have been examined in the current study are: the anchorage length, spacing, and configuration which were applied to the frame and infill wall and the added layer are on the inside or outside wall. A total of 11 specimen, 1/3 scale, one‐bay, one‐story nonductile RC frames with masonry infill wall which representing the deficiency in the existence building by using low‐compressive concrete, insufficient stirrups, and strong beam in comparison to column were constructed and tested under the effect of repeated seismic load. Load–displacement behaviors, initial stiffness, displacement ductility rates, and energy consumption capacities are interpreted.

References

17