Publication | Open Access
Hearing Screening in the Community
18
Citations
21
References
2018
Year
It is important to select screening locations with a quiet space for pure-tone screening, use headphones with good passive attenuation, measure sound levels regularly during hearing screening events, halt testing if ambient noise levels are high, and/or alert individuals to the possibility of a false-positive screening failure. The data substantiate prior findings that the relationship between pure-tone sensitivity and reported hearing loss changes with age. Although it might be possible to develop age-specific HHI-S failure criteria to adjust for this, such an endeavor is not recommended because perceived difficulties are the best predictor of hearing health behaviors. Instead, it is proposed that a public health focus on education about hearing and hearing loss would be more effective.