Alzheimer s & Dementia · 2018 · 829 citations · 33 references
MedicineNeurologyNeuroscienceClinical NeuroscienceDementiaNeurodegenerationAlzheimer DiseaseCerebrospinal Fluid BiomarkersCognitive ImpairmentDementia BiomarkersNeurodegenerative DiseasesNeurodegenerative DisordersAlzheimer Disease ProgressionAmyloid Beta PeptidesAmyloid Pet ImagingBiomarkersCerebrospinal Fluid TauClinical ProgressionMild Cognitive Impairment DiagnosisMild Cognitive Impairment Progression
The study examined whether fully automated Elecsys CSF immunoassays could match PET imaging and forecast clinical decline, using cutoffs derived from an independent cohort. Cutoffs for Elecsys Aβ1‑42, total tau/Aβ1‑42, and p‑tau/Aβ1‑42 were established against flutemetamol PET in BioFINDER and validated against florbetapir PET in ADNI, and the assays were applied to MCI patients to assess progression. CSF tau/Aβ and p‑tau/Aβ ratios showed 90–96% agreement with PET, predicted greater 2‑year decline in MCI, and matched semiquantitative PET accuracy, supporting Elecsys assays as reliable PET alternatives.
Abstract Introduction We studied whether fully automated Elecsys cerebrospinal fluid (CSF) immunoassay results were concordant with positron emission tomography (PET) and predicted clinical progression, even with cutoffs established in an independent cohort. Methods Cutoffs for Elecsys amyloid‐β 1–42 (Aβ), total tau/Aβ(1–42), and phosphorylated tau/Aβ(1–42) were defined against [ 18 F]flutemetamol PET in Swedish BioFINDER (n = 277) and validated against [ 18 F]florbetapir PET in Alzheimer's Disease Neuroimaging Initiative (n = 646). Clinical progression in patients with mild cognitive impairment (n = 619) was studied. Results CSF total tau/Aβ(1–42) and phosphorylated tau/Aβ(1–42) ratios were highly concordant with PET classification in BioFINDER (overall percent agreement: 90%; area under the curve: 94%). The CSF biomarker statuses established by predefined cutoffs were highly concordant with PET classification in Alzheimer's Disease Neuroimaging Initiative (overall percent agreement: 89%–90%; area under the curves: 96%) and predicted greater 2‐year clinical decline in patients with mild cognitive impairment. Strikingly, tau/Aβ ratios were as accurate as semiquantitative PET image assessment in predicting visual read–based outcomes. Discussion Elecsys CSF biomarker assays may provide reliable alternatives to PET in Alzheimer's disease diagnosis.
33
Guy M. McKhann, David S. Knopman, Howard Chertkow et al. · Alzheimer s & Dementia · 2011 · 18.8K citations · Full text
Marilyn S. Albert, Steven T. DeKosky, Dennis W. Dickson et al. · Alzheimer s & Dementia · 2011 · 10.2K citations
Reisa A. Sperling, Paul Aisen, Laurel Beckett et al. · Alzheimer s & Dementia · 2011 · 7.1K citations · Full text
Medicine, Neurology, Neuroscience +17
Hypothetical model of dynamic biomarkers of the Alzheimer's pathological cascade
Clifford R. Jack, David S. Knopman, William J. Jagust et al. · The Lancet Neurology · 2009 · 4.8K citations · Full text
Advancing research diagnostic criteria for Alzheimer's disease: the IWG-2 criteria
Bruno Dubois, Howard Feldman, Claudia Jacova et al. · The Lancet Neurology · 2014 · 3.3K citations · Full text