A 95.2% efficiency dual-path DC-DC step-up converter with continuous output current delivery and low voltage ripple

Se-Un Shin, Yeunhee Huh, Yong-Min Ju, Sung‐Won Choi, Changsik Shin, Young‐Jin Woo, Minseong Choi, Se-Hong Park, Younghoon Sohn, Min-Woo Ko,

2018 · 45 citations · 4 references

Concepts

Abstract

DC-DC boost converters are widely used to increase the supply voltage in various applications, including LED drivers, energy harvesting, etc. [1-5]. The conventional boost converter (CBC) is shown in Fig. 27.5.1, where the switches S <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> and S <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> are turned on and off alternately at φ <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> and φ <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> , respectively, and the inductor current (I <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">L</sub> ) is built up and delivered to the output. There are some critical issues in CBC because the output delivery current (I <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">S</sub> ) is not continuous. As a result, the I <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">L</sub> can be much larger than the load current (I <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">LOAD</sub> ) as φ <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> becomes longer. Since a bulky-size inductor having a low parasitic DC resistance (R <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">dcr</sub> ) is not usable for mobile applications with a strictly limited space, this large I <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">L</sub> results in significant conduction loss in the large R <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">DCR</sub> of a small-size inductor. Another issue is that the discontinuous I <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">S</sub> in φ <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> causes large voltage ripple (AV <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">OUT</sub> ) at the output. Moreover, switching spike voltages can cause over-voltage stress on the loading block due to large di/dt of I <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">S</sub> combined with parasitic inductances of the GND path.

References

4