Annals of Intensive Care · 2017 · 40 citations · 31 references
MedicineChild HealthPediatricsPulmonologyVentilationVentilator ManagementMechanical VentilationPatient-ventilator SynchronyRespiratory MonitoringVentilatory SupportAsynchrony QuantificationConventional Ventilation ModesCritical Care VentilationDiaphragm Electrical Activity MonitoringMechanical Ventilation In ChildrenVentilator AsynchronyVentilator MonitoringVentilator-induced Asynchrony
BACKGROUND: We aimed (1) to describe the characteristics of patient-ventilator asynchrony in a population of critically ill children, (2) to describe the risk factors associated with patient-ventilator asynchrony, and (3) to evaluate the association between patient-ventilator asynchrony and ventilator-free days at day 28. METHODS: In this single-center prospective study, consecutive children admitted to the PICU and mechanically ventilated for at least 24 h were included. Patient-ventilator asynchrony was analyzed by comparing the ventilator pressure curve and the electrical activity of the diaphragm (Edi) signal with (1) a manual analysis and (2) using a standardized fully automated method. RESULTS: Fifty-two patients (median age 6 months) were included in the analysis. Eighteen patients had a very low ventilatory drive (i.e., peak Edi < 2 µV on average), which prevented the calculation of patient-ventilator asynchrony. Children spent 27% (interquartile 22-39%) of the time in conflict with the ventilator. Cycling-off errors and trigger delays contributed to most of this asynchronous time. The automatic algorithm provided a NeuroSync index of 45%, confirming the high prevalence of asynchrony. No association between the severity of asynchrony and ventilator-free days at day 28 or any other clinical secondary outcomes was observed, but the proportion of children with good synchrony was very low. CONCLUSION: Patient-ventilator interaction is poor in children supported by conventional ventilation, with a high frequency of depressed ventilatory drive and a large proportion of time spent in asynchrony. The clinical benefit of strategies to improve patient-ventilator interactions should be evaluated in pediatric critical care.
31
Rapid Disuse Atrophy of Diaphragm Fibers in Mechanically Ventilated Humans
Sanford Levine, Taitan Nguyen, Nyali Taylor et al. · New England Journal of Medicine · 2008 · 1.6K citations · Full text
Life Sciences, Anatomy, Physiology +16
Patient-ventilator asynchrony during assisted mechanical ventilation
Arnaud W. Thille, Pablo Rodríguez, Belén Cabello et al. · Intensive Care Medicine · 2006 · 923 citations · Full text
Pediatric Acute Respiratory Distress Syndrome
Robinder G. Khemani, Lincoln Smith, Jerry J. Zimmerman et al. · Pediatric Critical Care Medicine · 2015 · 411 citations · Full text
Medicine, Child Health, Pediatrics +17