Physics in Medicine and Biology · 2017 · 11 citations · 24 references
MedicineOncologyRadiation OncologyClinical Radiation OncologyRadiation DosimetryTreatment PlanningDose CalculationMonte Carlo DosimetryPatient-specific DosimetryRadiation TherapyTreatment Planning Dose CalculationTreatment Planning PhysicsBeam Model ValidationDepth Dose DistributionMonte Carlo Dose ModelingMonte Carlo Dose SimulationMulti-leaf CollimationPatient-specific Dose CalculationPatient-specific Quality AssuranceTreatment Planning System Validation
(Accuray Inc., Sunnyvale, CA) treatment plans. The IDC framework uses an XML-format treatment plan as exported from the treatment planning system (TPS) and DICOM format patient CT data, an MC beam model using phase spaces, CyberKnife MLC beam modifier transport using the EGS++ class library, a beam sampling and coordinate transformation engine and dose scoring using DOSXYZnrc. The framework is validated against dose profiles and depth dose curves of single beams with varying field sizes in a water tank in units of cGy/Monitor Unit and against a 2D dose distribution of a full prostate treatment plan measured with Gafchromic EBT3 (Ashland Advanced Materials, Bridgewater, NJ) film in a homogeneous water-equivalent slab phantom. The film measurement is compared to IDC results by gamma analysis using 2% (global)/2 mm criteria. Further, the dose distribution of the clinical treatment plan in the patient CT is compared to TPS calculation by gamma analysis using the same criteria. Dose profiles from IDC calculation in a homogeneous water phantom agree within 2.3% of the global max dose or 1 mm distance to agreement to measurements for all except the smallest field size. Comparing the film measurement to calculated dose, 99.9% of all voxels pass gamma analysis, comparing dose calculated by the IDC framework to TPS calculated dose for the clinical prostate plan shows 99.0% passing rate. IDC calculated dose is found to be up to 5.6% lower than dose calculated by the TPS in this case near metal fiducial markers. An MC-based modular IDC framework was successfully developed, implemented and validated against measurements and is now available to perform patient-specific QA by IDC.
24
Louis Potters, Brian D. Kavanagh, James M. Galvin et al. · International Journal of Radiation Oncology*Biology*Physics · 2010 · 666 citations
Report of AAPM TG 135: Quality assurance for robotic radiosurgery
Sonja Dieterich, Carlo Cavedon, Cynthia Chuang et al. · Medical Physics · 2011 · 248 citations
Steven K. Seung, David A. Larson, James M. Galvin et al. · American Journal of Clinical Oncology · 2013 · 116 citations