EP Europace · 2017 · 60 citations · 5 references
MedicineCardiologyClinical CardiologyElectrophysiologyInterventional CardiologyCardiac ArrhythmiasCardiac PacingCatheter AblationImplantable Cardioverter-defibrillator CareIntracardiac ElectrophysiologyPacemaker CareArrhythmia DiagnosisArrhythmia EpidemiologyCardiac Implantable DevicesCardiac PacemakersDevice Implantation CareElectrophysiological StudyImplantable Cardioverter DefibrillatorsIntracardiac Pacing
Aims: To provide comprehensive information on the access and use of cardiac implantable electronic devices (CIED) and catheter ablation procedures in Africa. Methods and results: The Pan-African Society of Cardiology (PASCAR) collected data on invasive management of cardiac arrhythmias from 2011 to 2016 from 31 African countries. A specific template was completed by physicians, and additional information obtained from industry. Information on health care systems, demographics, economics, procedure rates, and specific training programs was collected. Considerable heterogeneity in the access to arrhythmia care was observed across Africa. Eight of the 31 countries surveyed (26%) did not perform pacemaker implantations. The median pacemaker implantation rate was 2.66 per million population per country (range: 0.14-233 per million population). Implantable cardioverter-defibrillator and cardiac resynchronization therapy were performed in 12/31 (39%) and 15/31 (48%) countries respectively, mostly by visiting teams. Electrophysiological studies, including complex catheter ablations were performed in all countries from Maghreb, but only one sub-Saharan African country (South Africa). Marked variation in cost (up to 1000-fold) was observed across countries with an inverse correlation between implant rates and the procedure fees standardized to the gross domestic product per capita. Lack of economic resources and facilities, high cost of procedures, deficiency of trained physicians, and non-existent fellowship programs were the main drivers of under-utilization of interventional cardiac arrhythmia care. Conclusion: There is limited access to CIED and ablation procedures in Africa. A quarter of countries did not have pacemaker implantation services, and catheter ablations were only available in one country in sub-Saharan Africa.
5
M.J. Pekka Raatikainen, Davíð O. Arnar, Béla Merkely et al. · EP Europace · 2017 · 319 citations · Full text
M.J. Pekka Raatikainen, Davíð O. Arnar, Béla Merkely et al. · EP Europace · 2016 · 71 citations · Full text
Medicine, Cardiology, Surgery +15
M.J. Pekka Raatikainen, Davíð O. Arnar, Katja Zeppenfeld et al. · EP Europace · 2015 · 69 citations
ZV Jama, Ashley Chin, Motasim Badri et al. · Cardiovascular journal of South Africa/Cardiovascular journal of Southern Africa · 2015 · 27 citations · Full text
J. C. Tantchou Tchoumi, Sara Foresti, Pierpaolo Lupo et al. · Cardiovascular journal of South Africa/Cardiovascular journal of Southern Africa · 2012 · 10 citations · Full text