The Bone & Joint Journal · 2017 · 64 citations · 19 references
MedicineSurgeryDistraction OsteogenesisSpinal BiomechanicsSpine SurgeryDistraction RateDistraction TechniquesPediatric ScoliosisPediatric Spine DeformityPediatric Spine SurgeryDistractionsGrowth RodsMagnetically Controlled Growing RodsMinimally Invasive CorrectionPediatric DistractionPediatric Scoliosis SurgeryRadiographic Evaluation Of ScoliosisSpinal Deformity Correction
Aims Magnetically controlled growing rods (MCGRs) allow non-invasive correction of the spinal deformity in the treatment of early-onset scoliosis. Conventional growing rod systems (CGRS) need repeated surgical distractions: these are associated with the effect of the ‘law of diminishing returns’. The primary aim of this study was to quantify this effect in MCGRs over sequential distractions. Patients and Methods A total of 35 patients with a maximum follow-up of 57 months were included in the study. There were 17 boys and 18 girls with a mean age of 7.4 years (2 to 14). True Distraction (TD) was determined by measuring the expansion gap on fluoroscopy. This was compared with Intended Distraction (ID) and expressed as the ‘T/I’ ratio. The T/I ratio and the Cobb angle were calculated at several time points during follow-up. Results The mean follow-up was 30 months (6 to 57). There was a significant decrease in the mean T/I ratio over time (convex rod at 3 months 0.81, sd 0.58 vs 51 months 0.17, sd 0.16, p = 0.0001; concave rod at 3 months 0.93, sd 0.67 vs 51 months 0.18, sd 0.15, p = 0.0001). A linear decline of the mean T/I ratios was noted for both convex rods (r 2 = 0.90, p = 0.004) and concave rods (r 2 = 0.81, p = 0.015) over 51 months. At the 24-month follow-up stage, there was a significant negative correlation between the mean T/I ratio of the concave rod with weight (r = -0.59, p = 0.01), age (r = -0.59, p = 0.01), and BMI of the child (r = -0.54, p = 0.01). Conclusions The ‘law of diminishing returns’ is also seen after serial distraction using MCGR. Compared to previously published data for CGRS, there is a gradual linear decline rather than a rapid initial decline in lengthening. In older, heavier children a reduced distraction ratio in the concave rod of the MCGR device is noted over time. Cite this article: Bone Joint J 2017;99-B:1658–64.
19
Dual Growing Rod Technique for the Treatment of Progressive Early-Onset Scoliosis
Behrooz A. Akbarnia, David Marks, Oheneba Boachie-Adjei et al. · Spine · 2005 · 613 citations
Dual Growing Rod Technique Followed for Three to Eleven Years Until Final Fusion
Behrooz A. Akbarnia, Lee Breakwell, David Marks et al. · Spine · 2008 · 351 citations
Lengthening of Dual Growing Rods and the Law of Diminishing Returns
Wudbhav N. Sankar, David L. Skaggs, Charles E. Johnston et al. · Spine · 2011 · 334 citations
Distress During the Induction of Anesthesia and Postoperative Behavioral Outcomes
Zeev N. Kain, Shu Ming Wang, Linda C. Mayes et al. · Anesthesia & Analgesia · 1999 · 332 citations
Medicine, Psychology, Surgery +14