MedicineOphthalmologyVision ScienceClinical Vision ScienceOcular ImagingOphthalmic SurgeryCataract AssessmentCataract EvaluationCorneal ImagingCorneal OpticsCorneal TopographyOcular BiometryCentral Corneal Thickness MeasurementCorneal DiameterCorneal Thickness AssessmentPostoperative Refractive PredictabilityRepeatabilityRepeatability EstimationRepeatability Of Corneal TopographySwept-source Optical Biometry
Purpose . To assess the repeatability and agreement of parameters obtained with two biometers and to compare the predictability. Methods . Biometry was performed on 101 eyes with cataract using the IOLMaster 700 and the Galilei G6. Three measurements were obtained per eye with each device, and repeatability was evaluated. The axial length (AL), anterior chamber depth (ACD), keratometry (K), white-to-white (WTW) corneal diameter, central corneal thickness (CCT), and lens thickness (LT) were measured and postoperative predictability was compared. Results . Measurements could not be obtained with the IOLMaster 700 in one eye and in seven eyes with the Galilei G6 due to dense cataract. Both the IOLMaster 700 and Galilei G6 showed good repeatability, although the IOLMaster 700 showed better repeatability than the Galilei G6. There were no statistically significant differences in AL, ACD, steepest K, WTW, and LT (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M1"><mml:mi>P</mml:mi><mml:mo>></mml:mo><mml:mn>0.050</mml:mn></mml:math>), although flattest K, mean K, and CCT differed (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M2"><mml:mi>P</mml:mi><mml:mo><</mml:mo><mml:mn>0.050</mml:mn></mml:math>). The proportion of eyes with an absolute prediction error within 0.5 D was 85.0% for the IOLMaster 700 and was 80.0% for the Galilei G6 based on the SRK/T formula. Conclusions . Two biometers showed high repeatability and relatively good agreements. The swept-source optical biometer demonstrated better repeatability, penetration, and an overall lower prediction error.
14
Sources of error in intraocular lens power calculation
Thomas Olsen · Journal of Cataract & Refractive Surgery · 1992 · 496 citations
Medicine, Ophthalmology, Surgery +17
Sabong Srivannaboon, Chareenun Chirapapaisan, Pratuangsri Chonpimai et al. · Journal of Cataract & Refractive Surgery · 2015 · 186 citations
Kathleen S. Kunert, Monika Peter, Marcus Blum et al. · Journal of Cataract & Refractive Surgery · 2016 · 150 citations