Journal of Medical Physics · 2017 · 14 citations · 12 references
MedicineOncologyRadiation OncologyRadiation DosimetryRadiation MeasurementTreatment PlanningQuality Assurance In DosimetryRadiation TherapyRadiation Treatment PlanningStereotactic RadiotherapyThree-dimensional Conformal RadiotherapyTreatment Planning Dose CalculationIntensity-modulated Radiation Therapy DosimetryIntensity-modulated Radiation Therapy Quality AssurancePre-treatmentRadiotherapy Plan EvaluationTreatment Plan EvaluationTreatment Planning DosimetryTreatment Quality AssuranceVolumetric Modulated Arc Therapy Dosimetry
AIM: The aim of this study is to assess the use of ArcCHECK (AC) as an alternative method to replace film dosimetry for pre-treatment quality assurance (QA) of three-dimensional conformal radiation therapy, intensity-modulated radiation therapy (IMRT), and volumetric-modulated arc therapy (VMAT) stereotactic ablative radiotherapy (SABR) treatment plans. MATERIALS AND METHODS: Twenty-five patients with a varied diagnosis of lung, spine, sacrum, sternum, ribs, scapula, and femur undergoing SABR were selected for this study. Pre-treatment QA was performed for all the patients using ionization chamber and film dosimetry. Measurements were also carried out on an AC phantom. The planned and measured doses from the AC device and EBT3 films were compared using four different gamma criteria: 2%/2 mm, 3%/2 mm, 3%/1 mm, and 3%/3 mm. RESULTS: The mean gamma passing rates at 3%/3 mm for all non-spine SABR cases were 98.79 ± 0.96 and 99.27 ± 1.03 with AC and films, respectively. The mean passing rates at 3%/2 mm for AC and films were 98.76 ± 0.42 and 99.43 ± 0.27 respectively for spine VMAT SABR, and 87.15 ± 2.45 and 99.79 ± 0.14 respectively for spine IMRT SABR. In the case of spine tumors, the gamma criterion was tightened due to the proximity of spinal cord to the planning target volume. Our results show that AC provides good results for all VMAT SABR plans. CONCLUSION: The AC results at 3%/3 mm were in good agreement with film dosimetry for most cases. We observed a significant reduction in QA time on using AC for SABR QA. This study showed that AC results are comparable to film dosimetry for all studied sites except for spine IMRT SABR.
12
A technique for the quantitative evaluation of dose distributions
Daniel A. Low, William B. Harms, Sasa Mutic et al. · Medical Physics · 1998 · 2.9K citations · Full text
Stereotactic body radiation therapy: The report of AAPM Task Group 101
Stanley Benedict, Kamil M. Yenice, D Followill et al. · Medical Physics · 2010 · 2.2K citations · Full text
Task Group 142 report: Quality assurance of medical acceleratorsa)
Eric Klein, Joseph Hanley, John E. Bayouth et al. · Medical Physics · 2009 · 1.6K citations · Full text