Journal of Applied Clinical Medical Physics · 2017 · 63 citations · 23 references
MedicineOncologyRadiation OncologyBiomedical ImagingRadiation DosimetryTreatment PlanningBreast Cancer RadiotherapyDeep Inspiration Breath HoldExternal Beam RadiotherapyRadiation TherapyRadiation Treatment PlanningTreatment Planning Dose CalculationBreath-hold RadiotherapyImaging-based DosimetryIntrafractional MotionIsocenter LocalizationLeft-sided Breast Cancer Radiation PlanningLeft-sided Breast RadiotherapyOptical Surface ScanningSurface-guided Radiotherapy
The aim of this study was to investigate potential dose reductions to the heart, left anterior descending coronary artery (LAD), and ipsilateral lung for left-sided breast cancer using visually guided deep inspiration breath-hold (DIBH) with the optical surface scanning system Catalyst™, and how these potential dosimetric benefits are affected by intrafractional motion in between breath holds. For both DIBH and free breathing (FB), treatment plans were created for 20 tangential and 20 locoregional left-sided breast cancer patients. During DIBH treatment, beam-on was triggered by a region of interest on the xiphoid process using a 3 mm gating window. Using a novel nonrigid algorithm, the Catalyst™ system allows for simultaneous real-time tracking of the isocenter position, which was used to calculate the intrafractional DIBH isocenter reproducibility. The 50% and 90% cumulative probabilities and maximum values of the intrafractional DIBH isocenter reproducibility were calculated and to obtain the dosimetric effect isocenter shifts corresponding to these values were performed in the treatment planning system. For both tangential and locoregional treatment, the dose to the heart, LAD and ipsilateral lung was significantly reduced for DIBH compared to FB. The intrafractional DIBH isocenter reproducibility was very good for the majority of the treatment sessions, with median values of approximately 1 mm in all three translational directions. However, for a few treatment sessions, intrafractional DIBH isocenter reproducibility of up to 5 mm was observed, which resulted in large dosimetric effects on the target volume and organs at risk. Hence, it is of importance to set tolerance levels on the intrafractional isocenter motion and not only perform DIBH based on the xiphoid process.
23
Risk of Ischemic Heart Disease in Women after Radiotherapy for Breast Cancer
Sarah C. Darby, Marianne Ewertz, Paul McGale et al. · New England Journal of Medicine · 2013 · 4K citations · Full text
Medicine, Cardiology, Oncology +17
Sarah C. Darby, Paul McGale, Carolyn Taylor et al. · The Lancet Oncology · 2005 · 1K citations
Breast Cancer Facts and Figures 2000
Cancer Practice · 2000 · 516 citations
Medicine, Oncology, Breast Oncology +11
Veerle A.B. van den Bogaard, Bastiaan D.P. Ta, A. van der Schaaf et al. · Journal of Clinical Oncology · 2017 · 503 citations · Full text