Physiological Reports · 2017 · 40 citations · 20 references
MedicinePharmacologyPhysiologyClinical PharmacologyGeneral PharmacologyPharmacodynamicsBlood Pressure ControlBlood Pressure ManagementBlood Pressure Signal AnalysisCardiac MedicationsCardiovascular MonitoringCardiovascular PharmacologyBaroreflex ControlBaroreflex PhysiologyBeat-to-beat Blood Pressure AnalysisBlood PressureBlood Pressure VariabilityBlood Pressure Variability AnalysisCross-correlation AnalysisHeartbeat Monitoring
Spontaneous oscillations of blood pressure (BP) and interbeat interval (IBI) may reveal important information on the underlying baroreflex control and regulation of BP We evaluated the method of continuously measured instantaneous baroreflex sensitivity by cross correlation (xBRS) validating its mean value against the gold standard of phenylephrine (Phe) and nitroprusside (SNP) bolus injections, and focusing on its spontaneous changes quantified as variability around the mean. For this purpose, we analyzed data from an earlier study of eight healthy males (aged 25-46 years) who had received Phe and SNP in conditions of baseline and autonomic blocking agents: atropine, propranolol, and clonidine. Average xBRS corresponds well to Phe/SNP-BRS, with xBRS levels ranging from 1.2 (atropine) to 102 msec/mmHg (subject asleep under clonidine). Time shifts from BP- to IBI-signal increased from ≤1 sec (maximum correlations within the current heartbeat) to 3-5 sec (under atropine). Plotted on a logarithmic vertical scale, xBRS values show 40% variability (defined as SD/mean) over the whole range in the various conditions, except twice when the subjects had fallen asleep and it dropped to 20%. The xBRS oscillates at frequencies of 0.1 Hz and lower, dominant between 0.02-0.05 Hz. Although xBRS is the result of IBI/BP-changes, no linear coherence was found in the cross-spectra of the xBRS-signal and IBI or BP We speculate that the level of variability in the xBRS-signal may act as a probe into the central nervous condition, as evidenced in the two subjects who fell asleep with high xBRS and only 20% of relative variation.
20
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Marek Malik, J. Thomas Bigger, A. John Camm et al. · European Heart Journal · 1996 · 15.3K citations · Full text
Nursing, Cardiology, Physiology +15
Spontaneous Cardiac Baroreflex in Humans
Joel L. Parlow, Jean–Paul Viale, G. Annat et al. · Hypertension · 1995 · 388 citations
Medicine, Cardiology, Pharmacology +13
Time-domain cross-correlation baroreflex sensitivity
Berend E. Westerhof, Janneke Gisolf, Wim J. Stok et al. · Journal of Hypertension · 2004 · 253 citations
Engineering, Cardiology, Physiology +17