Clinical and Experimental Ophthalmology · 2017 · 21 citations · 10 references
MedicineOphthalmologySurgeryClinical OptometryOphthalmic SurgeryRefractive SurgeryCataract ManagementGlaucomaGlaucoma MonitoringGlaucoma SurgeryIntraocular Pressure MeasurementOcular BiometryAmbulatory Intraocular Pressure MonitoringGlaucoma After Cataract SurgeryIntraocular Pressure AssessmentIntraocular Pressure Control After SurgeryOpen-angle Glaucoma ManagementPostoperative Glaucoma Follow-upPostoperative Intraocular Pressure MeasurementSurgical Outcomes In Glaucoma
IMPORTANCE: To investigate the long-term safety of a novel intraocular telemetric pressure sensor. BACKGROUND: Acquisition of accurate intraocular pressure (IOP) data is vital for sufficient medical care of glaucoma patients. Non-invasive self-tonometry with a telemetric IOP sensor can provide important information regarding the individual IOP profile. DESIGN: Retrospective analysis of long-term follow-up data assessed during outpatient visits in a university hospital. PARTICIPANTS: Six patients with open-angle glaucoma were included. Unfortunately, one patient passed away shortly after completion of the original 1-year study. METHODS: Within the scope of a prospective 1-year pilot clinical trial, a telemetric IOP sensor was inserted into the ciliary sulcus after intracapsular lens implantation during planned cataract surgery. Patients were regularly examined as outpatients even beyond the duration of the 1-year study. Data concerning sensor functionality, safety parameters and home self-tonometry were assessed. MAIN OUTCOME MEASURES: Long-term sensor functionality and safety. RESULTS: Sensor measurements were always successful in every patient. Additionally, home self-tonometry was conducted without any problems by every patient. The average follow-up period was 37.5 months (21-50 months). During this period, the average number of IOP measurements performed per patient was 1273 (223-2884 measurements). No severe adverse events were reported. A varying degree of pupillary distortion was observed after 6-12 months in every patient; this remained unchanged thereafter with only one exception. CONCLUSIONS AND RELEVANCE: Telemetric IOP sensors showed good functionality and tolerability during long-term follow-up. Non-invasive self-tonometry with a telemetric IOP sensor can provide useful additional data for future monitoring of patients with glaucoma.
10
Reduction of Intraocular Pressure and Glaucoma Progression
Anders Heijl · Archives of Ophthalmology · 2002 · 3.3K citations
An Exploratory Study of Factors Influencing Glaucoma Treatment Adherence
Jo Ellen Stryker, Allen D. Beck, Susan A. Primo et al. · Journal of Glaucoma · 2010 · 123 citations
Intraocular Pressure Measurement by Radio Wave Telemetry
Amit Todani, Irmgard Behlau, Mark Fava et al. · Investigative Ophthalmology & Visual Science · 2011 · 108 citations
Medicine, Ophthalmology, Surgery +14