Physics of Plasmas · 2017 · 16 citations · 15 references
Natural SciencesMaterials SciencePhysicsElectromagneticsElectronic MaterialsPlasma PhysicsExplosion HazardsNanowiresEnergy DepositionEnergy Deposition MeasurementEnergy Deposition ProfilesStratificationThermodynamic Forces
The density distribution and the energy deposition in dark and light transverse layers from stratification structures were measured and analyzed from electrical exploding wire experiments in vacuum. It is demonstrated that the differences in the areal density of the dark layer and light layer regions were about 2 × 1017/cm2 at 296 ns after voltage collapsed. This difference corresponded to an energy deposition difference of ∼2 eV/atom between the dark and light layers, which likely arises from a ±10% resistivity perturbation during the explosion, as suggested by combining a gas column expansion model and a thermodynamic model.
15
Thermal instability during an electrical wire explosion
V. I. Oreshkin · Physics of Plasmas · 2008 · 149 citations
Electrothermal instability growth in magnetically driven pulsed power liners
Kyle Peterson, D. B. Sinars, Edmund Yu et al. · Physics of Plasmas · 2012 · 126 citations
State of the metal core in nanosecond exploding wires and related phenomena
G. S. Sarkisov, P. V. Sasorov, K.W. Struve et al. · Journal of Applied Physics · 2004 · 114 citations
G. F. Swadling, S. V. Lebedev, G. N. Hall et al. · Review of Scientific Instruments · 2014 · 78 citations
Natural Sciences, Physics, Optics +16