The effects of irrigation volume to the heat generation during implant surgery

20

Citations

22

References

2017

Year

Abstract

The temperature difference of no irrigation group was significantly higher than 12 ml/min and 30 ml/min groups for all four drills (p<0.05), whereas no statistically significant difference was found between 12 ml/min and 30 ml/min irrigation groups. (p>0.05) The temperature difference of drill 1 is significantly higher than drills 2, 3 and 4 for no irrigation group. (p<0.05) The temperature differences of drill 1, 2 and 3 were significantly higher than the temperature difference of drill 4 for 12 ml/min irrigation group. (p<0.05) Conclusions: The heat generated during drilling is not directly proportional to the coolant volume. Given that certain amount of irrigation is applied, implant sites can be prepared safely without the need for additional irrigation, which may result in reduced visibility of the surgical site and therefore a suboptimal surgery.