NASA Technical Reports Server (NASA) · 1960 · 37 citations · 0 references
Open access
EngineeringMechanical EngineeringAir ConditioningHeat TransferThermal AnalysisCooling SystemsGas InjectionHeat Transfer AnalysisMachine CoolingCoolant Flow DynamicsCoolant Flow ModelingCoolant TechnologyCooling Performance EvaluationCooling System DesignCooling System Performance AnalysisFilm CoolingSlot Cooling
A study was made to determine the effect of coolant injection angularity on gaseous film-cooling effectiveness. In the correlation of experimental data an effective injection angle was defined by a vector summation of the coolant and mainstream gas flows. The cosine of this angle was used as a parameter to empirically develop a corrective term to qualify a correlating equation presented in Technical Note D-130 that was limited to tangential injection of the coolant. Data were also obtained for coolant injection through rows of holes normal to the test plate. The slot correlating equation was adapted to fit these data by the definition of an effective slot height. An additional corrective term was then determined to correlate these data.