Clinical outcomes of asleep vs awake deep brain stimulation for Parkinson disease
109
Citations
15
References
2017
Year
This study provides Class III evidence that for patients with PD undergoing DBS, asleep intraoperative CT imaging-guided implantation is not significantly different from awake microelectrode recording-guided implantation in improving motor outcomes at 6 months.